41
7.3.3
Cleaning, checking and replacing the squeegee blades
CAUTION
Wear protective gloves when cleaning the squeegee, as sharp debris may be attached
to it.
ATTENTION
In order to dry the floor properly, the squeegee must be clean and the blades in good
condition. The rear blade must have a square angle for effective cleaning.
TIP:
Daily cleaning can be done with the blades in the squeegee body. Clean the edges of the blades
with a damp cloth. Only step 1 and step 15 need to be done.
1.
To remove the squeegee body from the
squeegee lifting plate of the i-drive®, please
see section 7.3.1.
Removing the back blade (no holes).
2.
Loosen the small rotary knobs at both ends
of the squeegee (Figure 36, pos 1).
3.
Remove the clamping plate
(Figure 36, pos 2) of the back blade.
4.
Remove the back blade from the squeegee
frame (Figure 36, pos 3).
Figure 36