45
Fault code
(Hex)
Int. code
(Dec)
Meaning of the fault code
possible reason for fault detection
Reaction of the TCU
Possible steps to repair
Remarks
Logical error at internal speed input
TCU measures a internal speed over a
threshold and at the next moment the
measured speed is zero
Cable/connector is defective and has bad
contact
Speed sensor has an internal defect
Sensor gap has the wrong size
S.C. to battery voltage or O.C. at output
speed input
TCU measures a voltage higher than 12.5V
at speed input pin
Cable is defective and is contacted to
battery voltage
Cable has no connection to TCU
Speed sensor has an internal defect
Connector pin is contacted to battery
voltage or has no contact
S.C. to ground at output speed input
TCU measures a voltage less than 1.00V at
speed input pin
Cable/connector is defective and is
contacted to vehicle ground
Speed sensor has an internal defect
Logical error at output speed input
TCU measures a turbine speed over a
threshold and at the next moment the
measured speed is zero
Cable/connector is defective and has bad
contact
Speed sensor has an internal defect
Sensor gap has the wrong size
OP mode : Substitute clutch control
Special mode for gear selection
OP mode : Substitute clutch control
If a failure is existing at turbine
speed,
TCU shifts to neutral
OP mode : lamp home
Special mode for gear selection
OP mode : Substitute clutch control
If a failure is existing at turbine
speed,
TCU shifts to neutral
OP mode : lamp home
Special mode for gear selection
OP mode : Substitute clutch control
If a failure is existing at turbine
speed,
TCU shifts to neutral
OP mode : lamp home
Check the cable from TCU to
the sensor
Check the connectors
Check the speed sensor
Check the sensor gap
Check the cable from TCU to
the sensor
Check the connectors
Check the speed sensor
Check the cable from TCU to
the sensor
Check the connectors
Check the speed sensor
Check the cable from TCU to
the sensor
Check the connectors
Check the speed sensor
Check the sensor gap
This fault is reset after power
up of TCU
This fault is reset after power
up of TCU
https://www.forkliftpdfmanuals.com/
Summary of Contents for HDF 50-7S
Page 2: ...https www forkliftpdfmanuals com ...
Page 282: ...7 3 2 HDF50 70 7 https www forkliftpdfmanuals com ...
Page 283: ...7 3 MEMORANDUM https www forkliftpdfmanuals com ...
Page 316: ...https www forkliftpdfmanuals com ...
Page 318: ...https www forkliftpdfmanuals com ...
Page 330: ...https www forkliftpdfmanuals com ...
Page 353: ...3 1 SERVICE TOOLS 1 Special tool 3 2 https www forkliftpdfmanuals com ...
Page 360: ...https www forkliftpdfmanuals com ...
Page 378: ...https www forkliftpdfmanuals com ...
Page 408: ...https www forkliftpdfmanuals com ...
Page 428: ...https www forkliftpdfmanuals com ...
Page 506: ...ELECTRICAL SYSTEM 12 28 Installing alternator S6S Y3T62HF https www forkliftpdfmanuals com ...
Page 508: ...https www forkliftpdfmanuals com ...