![Hyundai HDF 50-7S Service Manual Download Page 461](http://html.mh-extra.com/html/hyundai/hdf-50-7s/hdf-50-7s_service-manual_2196429461.webp)
COOLING SYSTEM
10-5
2.2 Inspecting thermostat
CAUTION
Be careful of burns or a fire when measuring tempera-
ture, as it involves a high-temperature and open flame.
To test the thermostat operation, immerse the thermostat in a
container filled with water. Heat the water, while measuring
the water temperature. Record the temperature at the
conditions shown in the table below. If the temperatures are
not within the standard range, replace the thermostat.
Note: (a) Stir the water in the container with a stick to
ensure uniform temperature distribution.
(b) Before installing the thermostat, be sure to check
the valve opening temperature stamped on the
thermostat valve side face.
Inspecting thermostat
Item
Standard
Temperature at which valve starts opening
76.5 ± 1.5°C
[170 ± 3.5°F]
Temperature at which valve lift becomes
9 mm [0.35 in.] or more.
90 ± 1.5°C
[194 ± 2.7°F]
0
9
[0.35]
76.5 °C
[170°F]
V
alve lift mm [in.]
Temperature
90°C
[194°F]
https://www.forkliftpdfmanuals.com/
Summary of Contents for HDF 50-7S
Page 2: ...https www forkliftpdfmanuals com ...
Page 282: ...7 3 2 HDF50 70 7 https www forkliftpdfmanuals com ...
Page 283: ...7 3 MEMORANDUM https www forkliftpdfmanuals com ...
Page 316: ...https www forkliftpdfmanuals com ...
Page 318: ...https www forkliftpdfmanuals com ...
Page 330: ...https www forkliftpdfmanuals com ...
Page 353: ...3 1 SERVICE TOOLS 1 Special tool 3 2 https www forkliftpdfmanuals com ...
Page 360: ...https www forkliftpdfmanuals com ...
Page 378: ...https www forkliftpdfmanuals com ...
Page 408: ...https www forkliftpdfmanuals com ...
Page 428: ...https www forkliftpdfmanuals com ...
Page 506: ...ELECTRICAL SYSTEM 12 28 Installing alternator S6S Y3T62HF https www forkliftpdfmanuals com ...
Page 508: ...https www forkliftpdfmanuals com ...