6-11
Tilt backward position
(2)
D353HS11
When the tilt control lever is pulled back, the spool moves to the right and the neutral passage is
closed.
The oil supplied from the pump pushes up the load check valve(1) and flows into tilt cylinder
port(B2). The pump pressure reaches proportionally the load of cylinder and fine control finished by
shut off of the neutral passage.
The return oil from cylinder port(A2) flows into the tank via the low pressure passage.
https://www.forkliftpdfmanuals.com/
Summary of Contents for HDF 50-7S
Page 2: ...https www forkliftpdfmanuals com ...
Page 282: ...7 3 2 HDF50 70 7 https www forkliftpdfmanuals com ...
Page 283: ...7 3 MEMORANDUM https www forkliftpdfmanuals com ...
Page 316: ...https www forkliftpdfmanuals com ...
Page 318: ...https www forkliftpdfmanuals com ...
Page 330: ...https www forkliftpdfmanuals com ...
Page 353: ...3 1 SERVICE TOOLS 1 Special tool 3 2 https www forkliftpdfmanuals com ...
Page 360: ...https www forkliftpdfmanuals com ...
Page 378: ...https www forkliftpdfmanuals com ...
Page 408: ...https www forkliftpdfmanuals com ...
Page 428: ...https www forkliftpdfmanuals com ...
Page 506: ...ELECTRICAL SYSTEM 12 28 Installing alternator S6S Y3T62HF https www forkliftpdfmanuals com ...