GROUND
(TIERRA)
HYPOWER CONNECTIONS
(CONEXIONES HYPOWER)
GROUND
(TIERRA)
INCOMING THREE-PHASE POWER
(CORRIENTE TRIFÁSICA ENTRANTE)
L1 L2 L3
L1
L2
L3
GROUND
(TIERRA)
GROUND
(TIERRA)
INCOMING THREE-PHASE POWER
(CORRIENTE TRIFÁSICA ENTRANTE)
FIGURE 7A
FIGURE 7B
• HyPower Cabling Installation
• HyPower Cabling Components
Single-Sided Disconnect Box
This disconnect box has a 15 Amp service requirement and provides a dis-
connect means for up to 3 transfers at 230 volts or 6 transfers at 460 volts.
The maximum distance for any motor from this disconnect box is 50’. Any dis-
tance over 50’ requires an additional inline disconnect. (See fig. 7B & 7C)
Double-Sided Disconnect Box
This disconnect box has a 30 Amp service requirement and provides a dis-
connect means for up to 6 transfers at 230 volts or 12 transfers at 460 volts.
This disconnect box has the capability of covering 100’ of conveyor when
located in the middle of the span. Any motor further than 50’ from the discon-
nect box requires an additional inline disconnect. (See fig. 7A & 7d)
Double-Ended HyPower Extension Cable
Supplies power from the disconnect box down the conveyor to each HyPower
T-Connector. (See fig. 7C & 7d)
HyPower T-Connector
Power is supplied to the T-Connector via the Extension Cable. The
T-Connector is used as a power drop for each Variable frequency drive and
motor. (See fig. 7C & 7d)
Male Single-End HyPower Cable
This cable will come pre-wired to each Variable frequency drive as well as to
each divert motor. (See fig. 7C & 7d)
Female Single-End HyPower Cable
This cable will come pre-wired to each Variable frequency drive and supplies
power to each divert motor from the Variable frequency drive. (See fig. 7C
& 7d)
SINGLE SIDED DISCONNECT BOX
(CAJA DE DESCONEXIÓN DE UN SOLO LADO )
MALE SINGLE END HYPOWER CABLE
(CABLE HYPOWER MACHO DE
TERMINACIÓN “SINGLE-END”)
DOUBLE ENDED
HYPOWER EXTENSION CABLE
(CABLE DE EXTENSIÓN HYPOWER DE DOBLE TERMINACIÓN )
HYPOWER T-CONNNECTOR
(CONECTOR EN T HYPOWER)
FEMALE SINGLE END HYPOWER CABLE
(CABLE HYPOWER HEMBRA DE
TERMINACIÓN “SINGLE-END”)
MALE SINGLE END
HYPOWER CABLE
(CABLE HYPOWER MACHO
DE TERMINACIÓN “SINGLE-END”)
VFD
(VFD)
MOTOR
(MOTOR)
FEMALE SINGLE END
HYPOWER CABLE
(CABLE HYPOWER HEMBRA DE
TERMINACIÓN “SINGLE-END”)
DOUBLE SIDED DISCONNECT BOX
(CAJA DE DESCONEXIÓN DE AMBOS LADOS)
MALE SINGLE END
HYPOWER CABLE
(CABLE HYPOWER
MACHO DE TERMINACIÓN
“SINGLE-END”)
DOUBLE ENDED HYPOWER EXTENSION CABLE
(
CABLE DE EXTENSIÓN HYPOWER DE DOBLE TERMINACIÓN)
HYPOWER T-CONNNECTOR
(CONECTOR EN T HYPOWER)
MALE SINGLE END
HYPOWER CABLE
(CABLE HYPOWER
MACHO DE
TERMINACIÓN
“SINGLE-END”)
VFD
(VFD)
MOTOR
(MOTOR)
FIGURE 7C
SINGLE DICONNECT
FIGURE 7D DOUBLE DICONNECT
7