www.hytekintl.com
V240
PRESSIONE
- Pressione di esercizio: ________________________ da 1.5 a 6 bar
- Resistenza statica alla pressione: _____________________ 22 bar
PORTATA
- Portata di esercizio (Delta P = 1 bar): ________________ 10 mc/h
- Portata di lavaggio in controcorrente: ___________max 4 mc/h
- Portata del lavaggio lento: ________________ da 100 a 600 lt/h
- Portata lavaggio veloce in equicorrente: ______ max 5,5 mc/h
QUANTITATIVO MAX DI RESINA RIGERERABILE:
__________ 300 lt
TEMPERATURA DI ESERCIZIO:
____________________ da 5 a 40° C
MATERIALE CORPO VALVOLA:
_______________________ ABS + FV
RIGENERAZIONE IN EQUI-CORRENTE
- Cicli regolabili: _________________________ a seconda del timer
- Durata Massima disponibile: ___________ a seconda del timer
POTENZA ELETTRICA
_______________________________ vedi timer
CICLI DELLA RIGENERAZIONE
- 1) Controlavaggio _________________________ contro-corrente
- 2) Aspirazione _______________________________ equi-corrente
- 3) Lavaggio Lento __________________________ equi-corrente
- 4) Lavaggio Salamoia _____________ equi-corrente
- 5) Servizio______________________________________ equi-corrente
DIMENSIONI
- Attacchi Bombola (laterale):
______________ø ISO 40 incollaggio
- Conduttura allo scarico: __________________________ Ø 20 mm
- Conduttura alla salamoia: ____________________________ 3/8”
RACCORDI INGRESSO/USITA DISPONIBILI (A BAIONETTA)
- ¾ “ filetto femmina
- 1” filetto femmina
- 1 ¼ “ filetto femmina
- 1” ½ filetto femmina
- Ø ISO 32 femmina incollaggio
- ¾ “ NPT filetto femmina
- 1” NPT filetto femmina
- 1” ¼ NPT filetto femmina
- 1” ½ filetto maschio
- 2” filetto maschio
ACCESSORI/OPZIONI
- Vavola filtro
- Valvola per impianti di Demineralizzazione
- Valvola Salamoia
- By-Pass
- Produttore di cloro originale (solo abbinato con Timer ACL)
- No By-Pass Acqua grezza (a seconda del timer e con valvola
idropneumatica)
CERTIFICATI
- Conformità al DM 174 del 06/04/2004
- 2002/95/EC (RoHS)
V240
PRESSURE
- Operating Pressure: _______________________ from 1.5 to 6 bar
- Static resistance to pressure: _________________________ 22 bar
FLOW RATE
- Service Flow rate (1 bar drop): ______________________ 10 mc/h
- Backwash: _____________________________________max 4 mc/h
- Slow rinse: ______________________________ from 100 to 600 lt/h
- Fast rinse: ____________________________________ max 5,5 mc/h
MAXIMUM QUANTITY OF REGENERATIVE RESIN:
_________ 300 lt
OPERATING TEMPERATURE:
___________________ from 5 to 40° C
VALVE MATERIAL:
__________________________________ ABS + FV
DOWNFLOW REGENERATION
- Adjustable cycles: _____________________ depend on the timer
- Time available: _______________________ depend on the timer
ELECTRICAL RATE
__________________________________ see timers
REGENERATION CYCLE
- 1) Backwash _______________________________________ Upflow
- 2) Brine _________________________________________ Downflow
- 3) Slow Rinse _____________________________________ Downflow
- 4) Rapid Rinse + Brine Refill _______________________ Downflow
- 5) Servizice______________________________________ Downflow
DIMENSIONS
- Mounting lateral base:
________________________ ø ISO 40 glue
- Drain line: _________________________________________Ø 20 mm
- Brine line: _____________________________________________ 3/8”
PIPING FITTING IN/OUT AVAILABLE (BAYONET)
- ¾“ female thread
- 1” female thread
- 1 ¼“ female thread
- 1”½ female thread
- Ø ISO 32 female fitting to glue
- ¾ “ NPT female thread
- 1” NPT female thread
- 1” ¼ NPT female thread
- 1” ½ male thread
- 2” male thread
ACCESSORIES/OPTIONS
- Filter Valve
- Demineralization Valve
- Brine Valve
- By-Pass
- chlorine generator (sonly ACL Timer)
- No By-Pass raw water (depend on the timer and with
idropneumatic valve)
CERTIFICATES
- DM 174 DD April 06, 2004 compliance
- 2002/95/EC (RoHS)
V240