Power SuPPly SetuP
2-12
powermax
65/85
Service Manual
Extension cord length
< 10 ft
(< 3 m)
10 – 25 ft
(3 – 7.6 m)
25 – 50 ft
(7.5 – 15 m)
50 – 100 ft
(15 – 30 m)
100 – 150 ft
(30 – 45 m)
65 A CSA
Input voltage
(VAC)
Phase AWG (mm
2
) AWG (mm
2
) AWG (mm
2
) AWG (mm
2
) AWG (mm
2
)
200
–
240
1
8 (10)
8 (10)
8 (10)
6 (16)
4 (25)
480
1
12 (4)
12 (4)
12 (4)
10 (6)
10 (6)
200
–
240
3
10 (6)
10 (6)
10 (6)
8 (10)
6 (16)
400/480
3
12 (4)
12 (4)
12 (4)
12 (4)
12 (4)
600
3
12 (4)
12 (4)
12 (4)
12 (4)
12 (4)
65 A CE
Input voltage
(VAC)
Phase
mm
2
mm
2
mm
2
mm
2
mm
2
380
3
4
4
4
4
4
400
3
4
4
4
4
4
85 A CSA
Input voltage
(VAC)
Phase AWG (mm
2
) AWG (mm
2
) AWG (mm
2
) AWG (mm
2
) AWG (mm
2
)
200
–
240
1
6 (16)
6 (16)
6 (16)
4 (25)
2 (35)
480
1
10 (6)
10 (6)
10 (6)
8 (10)
8 (10)
200
–
240
3
8 (10)
8 (10)
8 (10)
6 (16)
4 (25)
400/480
3
10 (6)
10 (6)
10 (6)
10 (6)
10 (6)
600
3
10 (6)
10 (6)
10 (6)
10 (6)
10 (6)
85 A CE
Input voltage
(VAC)
Phase
mm
2
mm
2
mm
2
mm
2
mm
2
380
3
6
6
6
6
6
400
3
6
6
6
6
6
Extension cord specifications
Summary of Contents for Powermax 65
Page 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Page 10: ...vi powermax65 85 Service Manual ...
Page 16: ...Table of Contents xii powermax65 85 Service Manual ...
Page 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Page 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Page 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Page 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...