TroubleshooTing and sysTem TesTs
powermax
65/85
Service Manual
5-27
Fault
code
Description
(
System test number)
Power
LED
Fault
LED
Fault
icon
Solutions
0-98-0 Internal communication
failure
The control board and the
DSP are not communicating.
On
On
• Perform a cold restart.
• Confirm that the connecting ribbon cable is
installed properly between the control board
and the DSP board.
0-99-0 System hardware fault
(service required)
Indicates a major fault with
the system.
On
On
• Display the service screen.
• A qualified service technician must service
the system. Contact your distributor or
authorized repair facility.
1-nn-n
These fault codes usually relate to the DSP board and can only be seen on the service screen.
Fault
code
Description
(
System test number)
Power
LED
Fault
LED
Fault
icon
Solutions
1-00-0 Digital signal processor fault
On
On
These are internal processor checks and are
not likely to be caused by a hardware failure.
• Perform a cold restart.
If that doesn’t fix the problem, it is possible
that the DSP or Power board have failed.
1-10-0 A/D converter fault
1-20-0 I/O fault
Summary of Contents for Powermax 65
Page 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Page 10: ...vi powermax65 85 Service Manual ...
Page 16: ...Table of Contents xii powermax65 85 Service Manual ...
Page 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Page 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Page 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Page 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...