TroubleshooTing and sysTem TesTs
5-46
powermax
65/85
Service Manual
Test 5 – Flyback circuit (DC minor voltages)
Symptom: Minor voltages are not present.
Note: Wear proper personal protective equipment (PPE) before testing powered equipment.
The flyback circuit is the source of the minor DC voltages in the power supply. It pr3.3 VDC, +5 VDC, +24
VDC, and +48 VDC.
Check the voltages as described in the table. If a value is not within ±15%, perform the appropriate test later in this
section.
Volts DC
Test points (use chassis for negative)
CSA units
CE units
+48
J3 – Pin 1
J5 – Pin 1
+24
J1 – Pin 1
J3 – Pin 3
+5.0
J5 – Pin 3
J7 – Pin 3
+3.3
J11 – Pin 4
J14 – Pin 4
DSP board
J11 (CSA), J14 (CE)
Pin 4
J5 (CSA), J7 (CE)
Pin 3
Fan: J3 (CSA), J5 (CE)
Pin 4
Fan: J1 (CSA), J3 (CE)
Pin 1
Power board
Remove the connector covers to access the pins on the top-rear of the power board.
Summary of Contents for Powermax 65
Page 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Page 10: ...vi powermax65 85 Service Manual ...
Page 16: ...Table of Contents xii powermax65 85 Service Manual ...
Page 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Page 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Page 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Page 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...