85A Unshielded
Air flow rate - slpm/scfh
Mild Steel
Hot
190 / 400
Cold
235 / 500
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
mm
mm
mm
%
seconds
(mm/min)
Volts
(mm/min)
Volts
2
2.0
5.0
250
0.0
7150
117
10400
116
3
0.1
6240
118
9000
117
4
0.2
5250
118
7200
117
6
0.5
3450
120
4400
119
8
2400
121
3100
121
10
1560
123
2070
122
12
6.0
300
0.7
1200
126
1600
124
16
Edge Start
820
132
930
128
20
540
137
640
132
25
320
143
400
137
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
Voltage
in
in
%
seconds
ipm
Volts
ipm
Volts
14GA
0.08
0.20
250
0.1
280
117
416
116
10GA
0.2
230
118
328
117
3/16 in
175
119
220
118
1/4 in
0.5
125
120
160
119
3/8 in
65
122
86
122
1/2 in
0.24
300
0.6
42
127
56
125
5/8 in
Edge Start
33
131
37
128
3/4 in
23
136
27
131
7/8 in
18
140
21
134
1 in
12
144
15
138
Summary of Contents for Powermax 65
Page 1: ...Service Manual 807120 Revision 1 Plasma arc cutting systems ...
Page 10: ...vi powermax65 85 Service Manual ...
Page 16: ...Table of Contents xii powermax65 85 Service Manual ...
Page 32: ...Specifications 1 16 powermax65 85 Service Manual ...
Page 182: ...Troubleshooting and System Tests 5 56 powermax65 85 Service Manual ...
Page 216: ...Component Replacement 6 34 powermax65 85 Service Manual ...
Page 244: ...Wiring Diagrams 8 2 powermax65 85 Service Manual ...