TOPSIDE PANEL DISPLAY MESSAGES
Press:
Blower bu on on main control to ac vate system.
1) ON/OFF :
1
st
Press:
The Blower starts at maximum Speed. LED: ON
2
nd
Press:
The blower stops. LED: OFF
2) TO CONTROL SPEED:
Press and hold:
Speed goes up or down, LED: ON when pressing.
Release pressure at the desired speed.
3) TO CONTROL PULSATION:
1
st
Press:
Slow Pulsa on Cycle, LED: ON.
2
nd
Press:
Quick Pulsa on Cycle, LED: Flashes.
3
rd
Press:
Pulsa on Cycle OFF, LED: OFF.
1
2
3
Hr
-
An internal hardware error has been detected
Prr
-
The Prr error message indicates a problem with the regula on probe. The system is constantly verifying if the
temperature probe reading is within its normal limits.
HL
-
The water temperature at the heater has reached 119
o
F (48
o
C).
Do not enter spa water.
FLO
-
The system did not detect any water flow while the filtra on pump was running.
UPL
-
No low level configura on so ware has been downloaded into the system.
AOH
-
The temperature inside the spa skirt is too high, causing the internal temperature in the spa pack to
increase above the normal limits.
OH
-
The water temperature in the spa has reached 108
o
F (42
o
C).
Do not enter spa water.
OPTIONAL VARIABLE AIR THERAPYSYSTEM CONTROL FUNCTIONS:
BELLAGIO CONTROL FILTER
This filter must be cleaned at each drain and refill of your
swim spa to ensure proper func onality of the Bellagio
Waterfalls. It is located behind the door in the equipment
area. To access the filter screen turn large canister sec on
of the assembly counter
-
clockwise ll the apparatus
separates revealing screen filter. Run filter under tap to
clean out any debris and reassemble in reverse order.