
18
RELEASING AIR TRAPPED IN FILTER...
·
When the pump starts circula ng, it will be necessary to
release trapped air in the filter. Carefully loosen the air
vent valve counter
-
clockwise un l there is the hissing
sound of air escaping. Once there is a steady stream of
water, close the vent valve, ensuring that the o
-
ring
does not become pinched.
·
Turn the Hydrotherapy pump(s) on and re
-
check for
leaks. The control system will automa cally return the
pump(s) off a er 15 minutes.
·
Adjust the hot tub heat control at the topside panel to
the desired water temperature.
·
Adjust water balance (pH, TA, calcium hardness) to
recommended levels and add sani zer once the water
temperature reaches 20
o
C (68
o
F).
See sec on SWIM SPA WATER BALANCE
·
Keep insulated safety hard cover on the hot tub, and
the air controls closed during the en re heat up
process.
NOTE:
In order to prevent damage to your pillows caused by the
gassing effect of the chemicals, we do recommend to
remove them when the spa is not in use. By removing them
you will extend considerably the life length of your pillows.
We do design ours pillows to be removed easily in order to
make sure they will not remain in the spa when it’s not in
use.
AIR VENT VALVE
RELEASING AN AIR LOCK...
...
THROUGH THE PUMP UNION
Summary of Contents for 13FFP Aquaplay
Page 62: ...62 IN YE 3 EU WIRING DIAGRAM ...
Page 63: ...63 IN YE 3 NA WIRING DIAGRAM ...
Page 64: ...64 IN YE 5 EU WIRING DIAGRAM ...
Page 65: ...65 IN YE 5 NA WIRING DIAGRAM ...