30
KEYPAD SETTINGS
In this sec on you can change the
temperature unit and language. Use the
arrow keys and move to the se ng that you
would like to change. Use the Light key to
choose and the arrow keys to modify
For the temperature se ng you have a choice
between Fahrenheit or Celsius.
For the language se ng you have a choice
between English and French.
ELECTRICAL CONFIGURATION
Please do not make changes in this sec on
unless you are a qualified electrician.
ABOUT
This sec on shows informa on about the
keypad so ware number and the revision
numbers of the different components of your
system.
PURGE CYCLES
The purge cycles are programmed to begin at the start of each filter cycle. Pump 2 ac vates
for 1 minute, shuts off and then Pump 1 ac vates for 1 minute then shuts off.
SMART WINTER MODE
Smart Winter Mode protects your system from the cold by turning the pumps on several mes
a day to prevent water from freezing in the pipes. The Smart Winter Mode indicator turns on
when in this mode of opera on. If the temperature drops to 4
o
C (39
o
F) within the heater
chamber, the system automa cally ac vates the pump to provide freeze protec on. The
pump will operate un l the temperature reaches 5
o
C (41
o
F) before returning to normal system
mode.
COOLING DOWN
A er hea ng the spa water to the desired set point, the heater is turned off, but the filtra on
pump remains on for a certain amount of me to ensure adequate cooling of the hea ng
element in order to prolong the useful life of the heater. “Cooling to XX”F (”C)” message will
appear at the bo om of the screen.
Summary of Contents for 13FFP Aquaplay
Page 62: ...62 IN YE 3 EU WIRING DIAGRAM ...
Page 63: ...63 IN YE 3 NA WIRING DIAGRAM ...
Page 64: ...64 IN YE 5 EU WIRING DIAGRAM ...
Page 65: ...65 IN YE 5 NA WIRING DIAGRAM ...