8.10 Removing Inlet Solenoid Valve and Clean-
ing Fine Mesh Filter
Removal
»
Remove and open the steam cylinder as described
above in section “Removing and Cleaning the Steam
Cylinder - Removal.”
»
Seal off water supply and remove screw joint from fresh
water connection.
»
Detach connector hose from base.
»
Remove electrical connectors from solenoid.
»
Remove solenoid valve mounting screws.
»
Take the solenoid valve out of hole.
Cleaning
»
Remove fine mesh filter from the solenoid valve and
clean.
Installation
»
Place solenoid valve with seal in the hole in the unit
cabinet.
»
Secure solenoid valve tightly with screws .
»
Attach fresh water connection.
»
Connect elecrical cable to the solenoid valve.
»
Attach connector hose to the base by using clamps .
»
Install cylinder as described above in section “Cleaning
Steam Cylinder - Assembly”.
»
Open water supply.
»
Switch on unit and check for leakage after 15-30 min-
utes of operation.
If leakage occurs, switch off power supply and repair the leaks,
following safety instructions for work on live components!