Page 60
8.8 Unlocking of a Re leased Ther mo S ensor
(for heater element)
If a thermo sensor (for heater element) has released due to a too
high temperature the red release button (P) is some millimetres
above the level of the top of it s holder. Additional the co ntrol
reports a failure „thermo sensor activated“. After the system has
cooled down the release button (P) can be unlocked by pressing
it down a few millimetres.
8.9 Unlocking of a Re leased Ther mo S ensor
(for Solid State Relay)
If a th ermo sensor (for solid state relay) has release d due to a
too high temperature (>100°C +/- 5°K) the con trol reports a fail-
ure „thermo sensor activated“. After the system has cooled down
the release pin (that lays between the both plain connectors)
can be released by pressing it carefully down until there is a klick
sound.
Release
button