Hydromatic HP33 Owner'S Manual Download Page 2

SAFETY INFORMATION

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for
personal injury!

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.
The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

DESCRIPTION

These Submersible Sump Pumps are designed for home
sumps. The unit is equipped with a 3-prong grounding-type
power cord. The shaded-pole motor is oil filled and sealed for
cooler running. Upper sleeve/lower ballbearing on the motor
shaft never need lubrication. Automatic reset thermal
protection.

SPECIFICATIONS

Power supply required........................................115V, 60 HZ.
Liquid Temp. Range ..........................32°F to 130°F (0°-54°C)
Individual Branch Circuit Required:...........................15 Amps
Discharge ..............................................................1-1/2" NPT

PERFORMANCE

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption of
power to the pump, dirt/debris in the sump, flooding that
exceeds the pump’s capacity, electrical or mechanical failure
in the pump, etc.) may prevent your pump from functioning

normally. To prevent possible water damage due to flooding,
consult your dealer about installing a secondary sump pump,
a DC backup sump pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for information about
common sump pump problems and remedies. For more
information, see your dealer.

1.

Know the pump application, limitations, and potential
hazards.

2.

Disconnect the power before servicing.

3.

Release all pressure within the system before servicing
any component.

4.

Drain all water from the system before servicing.

5.

Secure the discharge line before starting the pump. An
unsecured discharge line will whip, possibly causing
personal injury and/or property damage.

6.

Check the hoses for a weak or worn condition before
each use. Make certain all connections are secure.

7.

Periodically inspect the sump, pump and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.

8.

Provide a means of pressure relief for pumps whose
discharge line can be shut-off or obstructed.

9.

Personal Safety:
a. Wear safety glasses at all times when working with

pumps.

b. Keep the work area clean, uncluttered and properly

lighted – replace all unused tools and equipment.

c. Keep visitors at a safe distance from work area.
d. Make the workshop child-proof – with padlocks,

master switches, and by removing starter keys.

10. When wiring an electrically driven pump, follow all

electrical and safety codes that apply.

11.

This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-
conductor cord and 3-prong, grounding-type plug.

Electrical shock hazard. Can burn or kill.

To reduce risk of electric shock, pull plug before
servicing. Pump is supplied with a grounding conductor
and grounding-type attachment plug. Be sure it is
connected only to a properly grounded grounding-type
receptacle.

Where a 2-prong wall receptacle is encountered, it must
be replaced with a properly grounded 3-prong receptacle
installed in accordance with codes and ordinances that
apply.

This pump has not been investigated for use in
swimming pool areas.

12. All wiring should be performed by a qualified electrician.
13. Make certain the power source conforms to the

requirements of your equipment.

14. Protect the electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immediately.

15. Do not touch an operating motor. Motors can operate at

high temperatures.

16. Do not handle the pump or pump motor with wet hands

or when standing on wet or damp surface, or in water.

2

GPM (LPM) AT TOTAL FEET (m)

5

10

15

20

Model

(1.5m)

(3m)

(4.6m)

(6.1m)

CAPACITY GALLONS(L)/MINUTE

HP33

48

40

29

15

24 Ft.

(182) (151)

(110)

(57)

(7.3m)

HP50

62

52

45

39

32 Ft.

(235) (197)

(170)

(148)

(9.8m)

No flow 

at height

shown

below

Full Individual

Model

Motor

Load

Branch Circuit

Cord

Number

HP

Amps

Required (Amps)

Length

HP33

1/3

9.8

15

10’

HP33-20

1/3

9.8

15

20’

HP33-30

1/3

9.8

15

30’

HP50

1/2

12.0

15

10’

HP50-20

1/2

12.0

15

20’

HP50-30

1/2

12.0

15

30’

MOTOR & CORD SPECIFICATIONS

Summary of Contents for HP33

Page 1: ...tien Composer le 1 888 957 8677 Fran ais Pages 7 11 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 888 957 8677 Espa ol...

Page 2: ...sonal injury and or property damage 6 Check the hoses for a weak or worn condition before each use Make certain all connections are secure 7 Periodically inspect the sump pump and system components Ke...

Page 3: ...rounded metallic raceway or ground wire system Do not modify the cord or plug or cut off the round ground pin 9 If the pump discharge line is exposed to an outside sub freezing atmosphere the portion...

Page 4: ...is plugged Turn off the pump clean out the anti airlock hole and restart pump TROUBLESHOOTING CHART 8 With the switch guard in place set the switch on the motor housing with the switch arm pointed tow...

Page 5: ...Rings and Gaskets Key Nos 2A 2B 2C 1 U9 471REP U9 471REP 3 Power Cord 10 1 PW117 237 TSU PW117 237 TSU Power Cord 20 1 PW17 122 PW17 122 Power Cord 30 1 PW17 293 PW17 293 4 Motor 1 5 Shaft Seal 1 2160...

Page 6: ...o request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Fi...

Page 7: ...d clater et causer des blessures corporelles et ou des d g ts mat riels 6 Avant d utiliser une pompe s assurer que les tuyaux souples ne sont pas d fectueux us s et que tous les raccords sont bien se...

Page 8: ...llation doit tre achemin e l autorit locale r glementaire Tension dangereuse Risque de secousses lectriques Toujours mettre la pompe la terre sur une terre lectrique ad quate comme un tuyau d eau mis...

Page 9: ...le saut Le remplacer par un fusible de calibre ad quat pas ou ne fonctionne pas Tension de ligne basse Si la tension est inf rieure la tension minimale recommand e v rifier le calibre du c blage c t d...

Page 10: ...es 1 U9 471REP U9 471REP r f n 2A 2B 2C 3 Cordon lectrique 10 1 PW117 237 TSU PW117 237 TSU Cordon lectrique 20 1 PW17 122 PW17 122 Cordon lectrique 30 1 PW17 293 PW17 293 4 Moteur 1 5 Joint d arbre 1...

Page 11: ...cune demande de service en vertu de sa garantie ne sera accept e apr s expiration de la dur e de sa garantie Ces garanties ne sont pas transf rables EXCEPTIONS Les pompes pour applications sp ciales l...

Page 12: ...a tuber a de descarga que no est bien segura puede moverse y causar lesiones personales y o da os materiales 6 Antes de cada uso verifique si las mangueras est n d biles o gastadas asegur ndose de que...

Page 13: ...o muerte La bomba siempre debe estar puesta a tierra por medio de una conexi n el ctrica a tierra adecuada como una tuber a de agua puesta a tierra una canalizaci n met lica debidamente puesta a tier...

Page 14: ...RRECTIVA La bomba no arranca Fusible quemado Si est quemado c mbielo por un fusible del tama o adecuado o no marcha Baja tensi n de l nea Si la tensi n se encuentra por debajo del m nimo recomendado v...

Page 15: ...P empaquetaduras Claves Nos 2A 2B 2C 3 Cord n el ctrico 10 1 PW117 237 TSU PW117 237 TSU Cord n el ctrico 20 1 PW17 122 PW17 122 Cord n el ctrico 30 1 PW17 293 PW17 293 4 Motor 1 5 Sello del eje 1 216...

Page 16: ...ra un problema No se aceptar ninguna solicitud de servicio bajo garant a que se reciba despu s del vencimiento del Per odo de Garant a Esta garant a no se puede transferir EXCEPCIONES Las bombas para...

Reviews: