- 10 -
3.8 Initial operation
Note: In order to heat the water in the pool (or hot tub), the filter pump must be running to cause the water to
circulate through the heat pump. The heat pump will not start up if the water is not circulating.
After all connections have been made and checked, carry out the following procedure:
1. Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
2. Connect power to the heat pump and press the On/Off button
on the electronic control panel. The unit will
start up after the time delay expires .
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump , the unit should also turn off automatically , if not, then adjust the flow switch.
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take
several days to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce
the required length of time.
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate .It will turn on wh
en the pool pump runs and shut it off when the pump shuts off. If the pool water level higher than 1 m above or b
elow the heat
pump’s automatic adjustment knob, your dealer may need to adjust its initial startup.
Time delay
‐
The heat pump has a built
‐
in 3
‐
minute start
‐
up delay to protect the circuitry and avoid excessive
contact wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will
trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions during this
delay period do not affect the 3
‐
minute duration of the delay.
3.9 Condensation
The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool water,
which may cause condensation on the fins of the evaporator. The amount of condensation may be as much as
several litres per hour at high relative humidity. This is sometimes mistakenly regarded as a water leak.
Summary of Contents for Inverter 07
Page 1: ...Swimming Pool Heat Pump User and Service manual English French Dutch German Polish Danish ...
Page 2: ......
Page 4: ......
Page 8: ... 4 2 Dimension mm Model Inverter 7 10 Model Inverter 14 ...
Page 9: ... 5 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 17: ... 13 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 7 10 14 17 21 ...
Page 18: ... 14 5 2 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 26 35 ...
Page 19: ... 15 5 3 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 26T 35T ...
Page 36: ... 32 2 Dimension Modèle Inverter 7 10 Modèle Inverter 14 ...
Page 37: ... 33 Modèle Inverter 17 Modèle Inverter 21 26 26T 35 35T ...
Page 46: ... 42 5 2 SCHEMA DE CABLAGE DE POMPE À CHALEUR DE PISCINE Inverter 26 35 ...
Page 47: ... 43 5 3 SCHEMA DE CABLAGE DE LA POMPE À CHALEUR DE PISCINE Inverter 26T 35T ...
Page 64: ... 60 2 Afmeting Dimension Model Inverter 7 10 Model Inverter 14 ...
Page 65: ... 61 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 73: ... 69 5 Elektrische bedrading 5 1 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Inverter 7 10 14 17 21 ...
Page 74: ... 70 5 2 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Inverter 26 35 ...
Page 75: ... 71 5 3 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Inverter 26T 35T ...
Page 92: ... 88 2 Ausmaße Model Inverter 7 10 Model Inverter 14 ...
Page 93: ... 89 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 102: ... 98 5 2 VERKABELUNGSDIAGRAMM DER SCHWIMMBECKEN WÄRMEPUMPE Inverter 26 35 ...
Page 103: ... 99 5 3 VERKABELUNGSDIAGRAMM DER SCHWIMMBECKEN WÄRMEPUMPE Inverter 26T 35T ...
Page 121: ... 117 2 Wymiary Model Inverter 7 10 Model Inverter 14 ...
Page 122: ... 118 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 131: ... 127 5 2 SCHEMAT OKABLOWANIA POMPY GRZEWCZEJ DO BASENOW KĄPIELOWYCH Inverter 26 35 ...
Page 132: ... 128 5 3 SCHEMAT OKABLOWANIA POMPY GRZEWCZEJ DO BASENOW KĄPIELOWYCH Inverter 26T 35T ...
Page 150: ... 146 2 Dimension mm Model Inverter 7 10 Model Inverter 14 ...
Page 151: ... 147 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 160: ... 156 5 2 SWIMMINGPOOL VARMEPUMPE WIRING DIAGRAM Inverter 26 35 ...
Page 161: ... 157 5 3 SWIMMINGPOOL VARMEPUMPE WIRING DIAGRAM Inverter 26T 35T ...
Page 175: ......
Page 176: ...A0111HYI04 ...