- 7 -
3.3 Distance from your swimming pool
The heat pump is normally installed within a perimeter area extending 7.5 m from the swimming pool. The greater
the distance from the pool, the greater the heat loss in the pipes. As the pipes are mostly underground, the heat
loss is low for distances up to 30 m (15 m from and to the pump; 30 m in total) unless the ground is wet or the
groundwater level is high. A rough estimate of the heat loss per 30 m is 0.6 kWh (2,000 BTU) for every 5 ºC
difference between the water temperature in the pool and the temperature of the soil surrounding the pipe. This
increases the operating time by 3% to 5%.
3.4 Check
‐
valve installation
Note: If automatic dosing equipment for chlorine and acidity (pH) is used, it is essential to protect the heat pump
against excessively high chemical concentrations which may corrode the heat exchanger. For this reason, equipment
of this sort must always be fitted in the piping on the
downstream
side of the heat pump, and it is recommended to
install a check
‐
valve to prevent reverse flow in the absence of water circulation.
Damage to the heat pump caused by failure to observe this instruction is not covered by the warranty.
Summary of Contents for Inverter 07
Page 1: ...Swimming Pool Heat Pump User and Service manual English French Dutch German Polish Danish ...
Page 2: ......
Page 4: ......
Page 8: ... 4 2 Dimension mm Model Inverter 7 10 Model Inverter 14 ...
Page 9: ... 5 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 17: ... 13 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 7 10 14 17 21 ...
Page 18: ... 14 5 2 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 26 35 ...
Page 19: ... 15 5 3 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 26T 35T ...
Page 36: ... 32 2 Dimension Modèle Inverter 7 10 Modèle Inverter 14 ...
Page 37: ... 33 Modèle Inverter 17 Modèle Inverter 21 26 26T 35 35T ...
Page 46: ... 42 5 2 SCHEMA DE CABLAGE DE POMPE À CHALEUR DE PISCINE Inverter 26 35 ...
Page 47: ... 43 5 3 SCHEMA DE CABLAGE DE LA POMPE À CHALEUR DE PISCINE Inverter 26T 35T ...
Page 64: ... 60 2 Afmeting Dimension Model Inverter 7 10 Model Inverter 14 ...
Page 65: ... 61 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 73: ... 69 5 Elektrische bedrading 5 1 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Inverter 7 10 14 17 21 ...
Page 74: ... 70 5 2 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Inverter 26 35 ...
Page 75: ... 71 5 3 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Inverter 26T 35T ...
Page 92: ... 88 2 Ausmaße Model Inverter 7 10 Model Inverter 14 ...
Page 93: ... 89 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 102: ... 98 5 2 VERKABELUNGSDIAGRAMM DER SCHWIMMBECKEN WÄRMEPUMPE Inverter 26 35 ...
Page 103: ... 99 5 3 VERKABELUNGSDIAGRAMM DER SCHWIMMBECKEN WÄRMEPUMPE Inverter 26T 35T ...
Page 121: ... 117 2 Wymiary Model Inverter 7 10 Model Inverter 14 ...
Page 122: ... 118 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 131: ... 127 5 2 SCHEMAT OKABLOWANIA POMPY GRZEWCZEJ DO BASENOW KĄPIELOWYCH Inverter 26 35 ...
Page 132: ... 128 5 3 SCHEMAT OKABLOWANIA POMPY GRZEWCZEJ DO BASENOW KĄPIELOWYCH Inverter 26T 35T ...
Page 150: ... 146 2 Dimension mm Model Inverter 7 10 Model Inverter 14 ...
Page 151: ... 147 Model Inverter 17 Model Inverter 21 26 26T 35 35T ...
Page 160: ... 156 5 2 SWIMMINGPOOL VARMEPUMPE WIRING DIAGRAM Inverter 26 35 ...
Page 161: ... 157 5 3 SWIMMINGPOOL VARMEPUMPE WIRING DIAGRAM Inverter 26T 35T ...
Page 175: ......
Page 176: ...A0111HYI04 ...