TROUBLESHOOTING
Issue
Possible Cause
Corrective Action
Low product flow
rate
Low driving pressure.
Increase feed pressure. Consider pump for low pressure locations.
Use short tubing runs to decrease flow restriction. Increase tubing
diameter for longer distances.
Low water temperature or high total dissolved solids (TDS).
Increase feed water temperature or feed pressure to compensate.
Plugged prefilter.
Replace plugged prefilter. Consider sediment prefilter for non-
chlorinated applications.
Scaled or fouled RO membrane.
Replace membranes.
Leak or kink in product line.
Find and repair leak or kink.
Concentrate water
runs to drain after
faucet shut off
Plugged prefilter
Replace plugged prefilter. Consider sediment prefilter for non-
chlorinated applications.
Leak in product line.
Find and repair leak. Install pressure gauge in product line to help
identify a product pressure leak.
Poor product water
quality
Water sample taken during system flush.
Take sample after three minutes of continuous operation.
Low driving pressure.
Increase feed pressure. Consider pump for low pressure locations.
Use short tubing runs to decrease flow restriction. Increase tubing
diameter for longer distances.
Plugged pre-filter.
Replace plugged prefilter. Consider sediment prefilter for non-
chlorinated applications.
Scaled, fouled, or damaged RO membrane.
Replace RO membranes.
Membrane stem o-rings damaged during installation
Replace both o-rings on membrane stem and lube properly before
installing
Hydro-Logic Purification Systems
370 Encinal Street, Suite 150
Santa Cruz, CA 95060
P: 888.426.5644
F: 831.336.9840
[email protected]
www.hydrologicsystems.com
For available options and add-ons,
contact Hydro-Logic directly
13
Summary of Contents for EVOLUTION-RO1000
Page 1: ...Installation Maintenance Manual ...
Page 16: ...GL4000442 RevA ...