Performance Specifications
Minimum and Maximum Operating Conditions
Condition
Minimum
Maximum
Inlet Pressure
40 psi (2.76 bar)
80 psi (5.52 bar)
Inlet Temperature
40
°
F (4.44
°
C)
100
°
F (37.78
°
C)
Inlet TDS
50 mg/L
2,000 mg/L
Inlet Hardness
0 mg/L (0 grain)
171 mg/L (10 grain)
Inlet Chlorine
0 mg/L
1.0 mg/L
Inlet Iron
0 mg/L
0.1 mg/L
Inlet Manganese
0 mg/L
0.05 mg/L
Inlet pH
4
10
Inlet Turbidity
0
1 NTU
(243.9)
9.6
(242.5)
9.55
(89.8)
3.53
(383.5)
15.10
(508.9)
20.03
(268.2)
10.56
(261)
10.27
(140)
5.51
(84.3)
3.32
(130.4)
5.13
(59.4)
2.34
(114.3)
4.50
(50.8)
2.0
(25.4)
1.0
Figure 9
Dimensions
12