20
-1500/-1700 IHT
CONTROL ARM ASSEMBLY
Refer to Figure 15, Page 21
DISASSEMBLY
RETURN TO NEUTRAL ASSEMBLY
1. Remove screw (88) and adjusting puck
(48).
2. Remove neutral spring (46), return arm (34),
and washer (87).
CONTROL ARM ASSEMBLY
1. Remove lower lock nut (95), and trunnion
spac er (106), from the trunnion arm (31).
2. Remove control arm (26).
3. Remove stud (36), if necessary.
INSPECTION
1. Inspect bearing (89), and replace if nec-
es sary. Remove bear ing by removing
coun ter sink screw (92), and spacer (90).
2. Inspect trunnion arm lip seal (33) and
re place if necessary. See page 22 for re-
place ment instructions.
ASSEMBLY
CONTROL ARM ASSEMBLY
1. Install new trunnion arm lip seal (33), into
main housing (1). See page 22 for in struc -
tions.
2. Install stud (36), per Table 5, Page 16.
3. Install control arm (26), onto trunnion arm
(31) and stud (36).
4. Install trunnion spacer (106) and lock nut
(95), per table 5, Page 16, onto the trunnion
arm (31).
NEUTRAL ASSEMBLY
NOTE: If bearing (89) must be replaced,
install bear ing (89), spacer (90), and
coun ter sink screw (92).
1. Install washer (87), return arm (34) and
neu tral spring (46).
2. Install adjusting puck (48), and bolt (88).
3. Reference page 13 for proper neu tral ad-
just ment procedures.