29
Hydrim L110W Preventative Maintenance Kit Installation Procedure
Remove All Covers
Removing the Top Cover
Using a flat screwdriver, release the latch
located at the back right of the unit.
Pull the cover back about ½”.
Lift the cover off.
Removing the Back Cover
Remove the screws in each corner of the panel.
Remove the panel.
Removing the Kick Plate
Remove the screws on both ends of the kick plate.
Do not loose spacer behind right side of kick plate.
Remove kick plate.
Removing the Left Side Panel
Open the door of the unit.
Remove the two screws from behind the doorframe.
Remove the screw below the back panel.
Remove panel.
Removing the Right Side Panel
Open the cleaning solution drawer (1).
Remove the screw holding the panel in place.
Remove screw (2) from inside top edge of front panel
above cleaning solution drawer.
Pry off the front panel above cleaning solution drawer.
Remove screw below the back panel.
Remove screw holding panel in place.