25
Checking & Programming Control Module
By pressing various combinations of buttons, it is possible to enter special cycles. To use these cycles,
hold the two buttons indicated and power the unit on.
1.
“regeneration (salt) level set”
: By pressing buttons P1 & P2 while powering the unit on the
display shows “L” on the first digit and the actual value of the regeneration level. Adjustment
from 0 to 7 can be made with button P0 (down) & P1 (up).
2.
“reset drying cycle counter”
: By pressing buttons P0 & P2 while powering the unit on the
display shows “c” and the first number of the actual drying cycle count followed by the last two
digits of the drying cycle count. (For example if the drying cycle count is 739 then it will
display c7 followed by 39) Pressing button P3 will reset the counter to “0”.
3.
“device test cycle”
: By pressing buttons P2 & P3 while powering the unit on the chamber fills
with water, then the dosing pump runs for 20 seconds. During this time whenever button P3 is
pressed the regeneration valve and salt indicator LED will start for 10 seconds.
4.
“repeater mode”
: By pressing buttons P2 & P4 while powering the unit on, the unit starts in
idle mode with a flashing “00” on the display. A program selected in this mode will run until
the unit is powered off with 10 minutes pause between cycles.
5.
“unit set”
: By pressing buttons P0 & P3 while powering the unit on the user can select among:
a)
“set wash time”
: The display shows “tI” followed by the actual value of the wash time.
Adjustment from 5 to 99 minutes can be made with P0 (down) and P1 (up). Default
valve is 05 minutes.
b)
“set wash temperature”
: The display shows “tE” followed by the actual value of the
wash temperature. Adjustment from 15 to 99 can be made with P0 (down) and P1 (up).
Default value is 50
°
C.
c)
“set drying time”
: The display shows “dt” followed by the actual value of the drying
time. Adjustment from 10 to 20 minutes can be made with P0 (down) and P1 (up).
Default value is 10 minutes.
6.
“software revision”
: By pressing buttons P3 & P4 while powering the unit on the display
shows “r” in the first digit followed by the first digit of the revision number and then the last
two digits. (For example if the revision is 2.01 then the display will show r2 followed by 01).