FT 5
Oil filter unit
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 25 / 44
Bewa FT5 3160334d en-us 2012-03-14.doc
2012-03-14
Oil filter unit
Area of utilization
The oil filter unit is used for off-line filtration on hydraulic tanks. The integrated change-
over valve means that, as well as off-line filtration, the tank can be filled and drained
without filtration using the unit.
Suitable fluids
NOTICE
Impermissible operating conditions
The unit will be damaged
►
The unit may be used only in connection with the media mentioned below.
The units are only suitable for pumping mineral oils and fluids based on mineral oils.
Under no circumstances must they ever be used for water, aggressive fluids, acids or
solvents. Even short applications with these fluids will invariably cause damage to the
pump.
Observing medium / ambient temperature
The device is designed for a viscosity range of 15 to 800 mm²/s. Observe the maximum
medium temperature of 80° C and observe the maximum ambient temperature of 40
°C.