FT 5
Connecting the filter pump unit
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 23 / 44
Check direction of rotation
Check the direction of rotation of the motor by switching it on briefly (jog mode).
The FT5 requires a clockwise rotating field at the connection socket.
NOTICE
Incorrect phase sequence / rotation direction of the motor
The pump will be destroyed.
►
In jog mode, check the direction of rotation of the motors.
►
A rotation direction arrow on the fan cover of the motor identifies the correct
direction of rotation.
If the direction of rotation is opposite to the direction of the arrow, rotate the phases in
the 16A / 32 A connection plug using the phase inverter in the connection plug.