FT 5
Connecting the filter pump unit
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 21 / 44
Connecting the filter pump unit
Hanging / connecting the suction hose
NOTICE
Contamination too high
The unit will be damaged
►
Do not prime directly at the bottom of the tank
►
Do not prime in the sump
►
Never prime without a built-in suction screen
The greatest contamination is found on the bottom of the tank. All
impurities and other particles are deposited on the bottom of the tank.
Pull the suction hose (thick, transparent hose) with lance out of the mounting in the
floor plate.
Put the suction hose with lance, without tension and or twist, into the appropriate
container and secure it against falling out.
Hanging / connecting the pressure hose
Pull the pressure hose (thinner, transparent hose) with lance out of the mounting in the
floor plate.
Put the pressure hose with lance, without tension and or twist, into the appropriate
container and secure it against falling out.
To prevent air from entering the medium, make sure that the pressure
hose with lance is always below the oil level in operation.
Electrical connection of the FT5
DANGER
Electric shock
Danger of fatal injury
►
Any work involving the electrical system may only
be done by a properly trained, certified electrician.
Bewa FT5 3160334d en-us 2012-03-14.doc
2012-03-14