HYDAC FILTER SYSTEMS GMBH
Operation | 7
BeWa FCU1310 3371346g en-us lq
79 / 148
See also
2
Putting the FCU into operation [
7.3.2 Measuring up to max. 45 bar / 650 psi with
hydraulic fluids
For the measurement of permissible hydraulic fluids up to a
maximum of 45 bar / 650 psi, proceed as follows:
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
u
The system must be depressurized before performing any
work on the product.
u
If the pressurized connection is connected to the hydraulic
system, hydraulic fluid will flow through the FCU.
u
Make sure that the specified sequence is followed.
NOTICE
If the operating pressure exceeds 45 bar / 650 psi
The excess pressure will be discharged via port OUTLET
u
Never seal the connection OUTLET.
u
Put the free end of the OUTLET return hose into an un-
pressurized container.
u
When operating, always observe the permissible operating
pressure.
Required hoses:
-Return hose
-High-pressure hose
Summary of Contents for FCU 1310