ContaminationSensor – CS 2000 series
HYDAC Filtertechnik GmbH
en
Page 78
BeWa CS2000 3117721e en.doc
2008-03-28
20.4 Factory default settings
Description
Value
t
Measurement time
30 s
m
Select measuring mode
M2
Limits mode M2 relay 1
8=ISO code,
4=fall below
16/13/10 (lower limit)
18/15/12 (upper limit)
2
Limits mode M2 relay 2
8=ISO code,
4=fall below
16/13/10 (lower limit)
18/15/12 (upper limit)
3
Limits mode M3
1=ISO
18/15/12
1=ISO
18/15/12 (lower limit)
22/19/16 (upper limit)
4
Limits mode M4
Test cycle time
60 min.
b
Set DIN bus address and
name
Address:
1
Name:
HYDAC CS2000
f
Flow check
Not used
p
Pump protection time
0 s
o
PLC output format
1=ISO
r
RS232 display output format Header:
Display:
1=ISO
i
Current output format
1=SAE class / NAS class
Analog input mode
(
0= no analog input)
Channel 1
a
Configure 4..20 mA input
Channel 2
e
IP address
192.168.0.30
d
Set default values
Sets all parameters to the values in this table.