Installation and Operation
HYDAC Filtertechnik GmbH
en
Page 32
BeWa CS1000 3247149k en.doc
2006-04-06
Measuring
Menu:
Description
DSPLAY
Select measured variable for display
SWtOUT
Configure switching output
ANaOUT
Select measured variable for analog
output
CANCEL
Discard changes and exit
SAVE
Save changes and exit
Display — Select displayed measured variable when switching on the sensor
DSPLAY
Select displayed
measured variable
Description
ISO
3-digit ISO code
SAE A
SAE class A
SAE B
SAE class B
SAE C
SAE class C
SAE D
SAE class D
SAeMAX
SAE A-D
FLOW
Flow rate [in ml/min]
ANaOUT
Analog output [in mA]
DRIVE
LED current [in %]
TEMP C
Fluid temperature in °C (Celsius)
TEMP F
Fluid temperature °F (Fahrenheit)
MODE – Configure measuring mode
Configure the switching mode selected in the Power Up Menu.
MODE
Configure switching
output
Description
M1
Measure continuously
M2
Measure continuously and switch
M3
Filter down to contamination level
and stop
M4
Filter to establish contamination
levels continuously
SINGLE
Perform single measu stop
M1
Measure continuously
NO SET