Adjusting the counter balance valve
8. When the operating medium is at
maximum viscosity, set the
pressure range to between
25 and 40 bar by turning the
adjusting screw at the load
holding valve with a 4-mm Allen
wrench.
NOTICE
With the product version CSM-
E …
-4
, a maximum pressure
increase of 25 bar is possible.
9. Tighten the lock nut. Make sure
that the setting of the counter
balance valve is not changed in
the process.
10. Screw the head-nut onto the
counter balance valve and
tighten it firmly.
11. Unscrew the pressure gauge (B)
from the gauge port.
The gauge port can remain in the
CS.
12. The unit is ready for operation.