Making the hydraulic connections to the unit
Installing additional sensor(s) AS1000 / AS3000 / HLB1400
Install the additional sensor AS1000, AS3000 or HLB1400 as follows:
1. Remove the screw plug (23).
2. Use a lint-free cloth to clean the sealing surface at the additional
sensor (31) and at the connection block.
3. Screw the additional sensor (31) by hand in a clockwise direction into
the cavity.
4. Tighten the additional sensor tight using a fork wrench = 27 mm
(torque : 20 +2 Nm).
5. The installation of the additional sensor (31) is complete.
CSM-E
en(us)
Page 25 / 64
MoWa CSM-E 3911629a en-us 2017-12-11.docx
2017-12-11
Summary of Contents for CSM-E
Page 54: ...Technical Data CSM E en us Page 54 64 MoWa CSM E 3911629a en us 2017 12 11 docx 2017 12 11 ...
Page 62: ......