Connection Diagram
Voltage loss over distance is caused as a function of control amperage multiplied by the resistance of
the wiring, and may be expressed:
Voltage loss =
(
wire resistance
)
X
(
control amperage
).
This
limits pushbutton control wiring to the following schedule:
16 ga. wire= up to 125 feet max
12 ga. wire = up to 300 feet max
14 ga. wire = up to 200 feet max10 ga. wire = up to 500 feet max
For applications requiring pushbutton controls from a long distance, or circuits of limited current,
order the factory modification, long range interface. The following schedule indicates the improved
control range using the long range interface:
16 ga. wire = up to 50 miles
20 ga. wire = up to 19 miles
18 ga. wire = up to 30 miles
22 ga. wire = up to 12 miles
Be certain to remove factory-installed jumper (#2 to #4) and also verify that no other external stop
button is connected at #2 and #4.
When the long range interface option is used in conjuction with a pushbutton control, connect to the
operator as shown below:
FOR BEST PERFORMANCE
USE 20 GAUGE WIRE OR LARGER
OPEN
CLOSE
STOP
COM
STP
CLS
OPN
LT. GREEN
LT. BLUE
ORANGE
YELLOW (COM)
DK BLUE
DK GREEN
BLACK
BLACK
24V SUPPLY
RED
WHITE
(COM)
4
2
3
1
10
2
TO
TO
C
O
O
P
N
E
T
R
R
A
O
T
L
O
S
R
REMOTE PUSHBUTTON
LONG RANGE
INTERFACE
TERMINAL
STRIP
NOTE:
The part number for the long range interface, installed at the factory, A EIIF 001 OCS
The same part designation for the long range interface, in kit form, A EKIF 001 OCS
5/10/00 E71