The procedure for manual operation of the vertical
lift gate in case of power failure or a serious
malfunction is as follows:
1. Turn off all electrical power to the controller.
2. Remove the lower access covers on both posts.
3. Remove the Allen head bolt in the three inch
sprocket at the end of the hydraulic motor in each
post. The gate will now operate like an old "sash
weight" type window, with friction as it's only
resistance.
4. Be certain to tie a rope to the bottom of the gate
panel so it can be pulled down again.
5. When the automatic operation is again ready,
reverse the above procedures.
EMERGENCY OPERATION PROCEDURES