C:\TEMP\ml59101.doc | Revised: 20JUN18 | Page 37 of 39
COMPRESSOR HARNESS FROM
NORMALLY OPEN AIR SOLENOID (1)
COMPRESSOR DIAGRAM
12 VOLT RELAY (2)
AIR FILTER
25JUL11
MP84.6085
AIR LINE TO SUSPENSION
CHECK VALVE (3)
GRAY FROM
AIR SOLENOID
GROUND
FUSE
15 AMP
FLOW
GROUND TO RELAY MOUNTING BOLT
TO +12 BATTERY
POWER - 6100
The control box sends a +12 signal to the normally open
12 volt relay. The 12 volt relay (2) will energize and the
compressor will run. The normally open air solenoid (1)
will close allowing the compressor to build pressure.
The normally open air solenoid (1) will open any time the
compressor is not running, allowing internal pressure &
moisture to bleed off. The check valve (3) will keep the
suspension air from bleeding back to the compressor.
ELECTRICAL CONNECTION DIAGRAM
FRONT AIR MANIFOLD I/O MODULE - (BLACK) 9700