![HWH 700 Series Service Manual Download Page 26](http://html1.mh-extra.com/html/hwh/700-series/700-series_service-manual_2190642026.webp)
C:\TEMP\ml59101.doc | Revised: 20JUN18 | Page 26 of 39
MP74.2670A
05SEP14
AIR SOLENOID MANIFOLD
6 VALVE WITH TWO PRESSURE SWITCHES
AND BY-PASS VALVES
EXHAUST
AXLE AIR IN
[ HCV ]
L
E
F
T
BY-PASS
VALVE
R
I
G
H
T
AIR
IN
BAG
R
BAG
PSW
BY-PASS
VALVE
BAG
CHECK VALVES
AIR SUPPLY
AIR BAGS
LINE TO
CONTROL
HEIGHT
LINE FROM
VALVES
3.400"
FRONT AIR MANIFOLD
RIGHT SIDE
VIEW
LEFT AND RIGHT
MOUNTING HOLES
LINE FROM HEIGHT
CONTROL VALVE (MAY BE
TEED TOGETHER IF ONE
EXHAUST PORTS
(2 LEFT AND RIGHT)
PRESSURE SWITCH
20 PSI (2 LEFT AND RIGHT)
LINE TO AIR BAGS
(2 LEFT AND RIGHT)
BE INTERCHANGED.
AIR SOLENOID VALVES CANNOT
FOR AIR PRESSURE SWITCHES AND
AS SHOWN. GROUND SUPPLY WIRES
CONNECTIONS MUST BE MAINTAINED
PRESSURE
REGULATOR
AIR SUPPLY
HCV IS USED)
IMPORTANT:
SOLENOID VALVE (LEFT
VALVE NOT SHOWN)
VALVE NOT SHOWN)
RIGHT RAISE
VALVE (2)
CHECK
RIGHT TRAVEL
SOLENOID VALVE (LEFT
VALVE NOT SHOWN)
RIGHT LOWER
SOLENOID VALVE (LEFT
A
A
B
B A
B A
B
PSW
RS
B A
B A
B
B
A
A
B
B
A
A
B
B
A
B
A
A
B
B
B
A
A
A
NASON
MODEL SM
REAR VIEW
SWITCHES (2)
PRESSURE
PRESSURE REGULATOR
RAISE
RS
LOWER
RS
RS
TRAVEL
LS
TRAVEL
LOWER
LS
RAISE
LS
PSW
LS
TRAVEL
RS
LOWER
RS
PSW
LS
RAISE
LS
LS
LOWER
TRAVEL
LS
RAISE
LS
PSW
LS
TO HARNESS
CONNECTOR
I/O MODULE CONNECTIONS
NOTE: I/O MODULE NOT SHOWN
SEE ELECTRICAL CONNECTION DIAGRAM
FRONT AIR I/O MODULE - PAGE 2 OF 2
(REGULATOR WILL NOT BE PRESENT
ON 2014 MODEL COACHES OR NEWER)