Electrode
and
nozzle work life is
very short.
1, Gas pressure is two low
2, Nozzle is too close to work-piece.
The distance is less than 2mm.
3. Nozzle aperture is small, and not
matched with applied current.
4. Electrode and nozzle is under
quality problem.
5. The torch bought by user himself is
under quality problem.
1
.
Adjust gas pressure
2
.
The distance should be within 2mm to
5mm
3. Select a proper nozzle matched with
applied current.
4. Change a good quality electrode and
nozzle.
5. Buy a good quality torch.
/
9.supply power trips
1.three phases rectifier is damaged.
2.IGBT module is damaged.
3.other components in main control
circuit is damaged.
1.change a three phases rectifier under
same model.
2.change IGBT module under same model.
3.check
and
change
the
damaged
components.
No arc striking, and
guiding arc spraying
out, but there is
high frequency.
1. Fast recovery diode of secondary
rectifying is damaged.
2. High frequency board PL13 is
damaged.
3. High frequency leakage in cutter
output circuit.
1. Change fast recovery diode under same
model.
2. Check and change the damaged
frequency board PL13.
3. Check leakage point, and strengthen
insulation function.
/
Supply power trips
1. Three phases rectifier is damaged.
2. IGBT module is damaged.
3. Other components in main control
circuit is damaged.
1. Change a three phases rectifier under
same model.
2. Change IGBT module under same model.
3.Check
and
change
the
damaged
components.
Sheet 6: Error code and troubleshooting
If got any problems not included in this sheet and cannot solved, please try to contact
the local agent or the manufacture.
11.3
Some popular components sheet as below:
No. Components name
Components Model
Components code
Remarks
1.
IGBT module
2MBI100VA-120
V2
、
V3
LGK-120HD
CM200DC-24NFM
LGK-200HD
CM150DC-24NFM
V3~V6
LGK-300
、
400HD
2.
Hall sensor
TKC200BR
TA1
、
TA2
LGK-120
、
200HD
TA3
、
TA4
LGK-300
、
400HD
TKC500BR
TA5
LGK-300
、
400HD
3.
Air breaker
DZ47-63/3P D63
QF1
LGK-120HD
CDB2-125/3P/D80
LGK-200HD
4.
AC contactor
CJ20-100/380V
KM1
LGK-300
、
400HD
5.
Controlling
transformer
TL07
TM1
6.
Electropneumatic
valve
DF2-3B-AC36V(3mm) G1/8
YV1
Q-5AC36V(5mm) G1/8
YV2
7.
Cooling fan
200FZY2-D/AC220
EV1
LGK-120HD