Technical Parameters
4.1
Main Technical Parameters
LGK-120HD
LGK-200HD
LGK-300HD
LGK-400HD
Rated input voltage
3
~
380/415V 50/60Hz
Rated input capacity
21.23VA
46.5kVA
70.42kVA
92.34kVA
Rated output current
120A
200A
300A
400A
Rated output voltage
128V
160V
200V
200V
Rated duty cycle
100%
100%
100%
100%
Open circuit voltage
308VDC
319VDC
370 VDC
370VDC
Current adjust range
30
~
120A
40
~
200A
60
~
300A
60
~
400A
Quality Cutting Thickness
(Carbon steel, manual cutting)
0.3
~
25mm
1
~
45mm
1
~
50mm
1
~
60mm
Max. Cutting Thickness
(Carbon steel, manual cutting)
45mm
65mm
80mm
90mm
Plasma gas
Compressed Air
The working plasma gas
pressure
0.3
~
0.5MPa
0.4
~
0.6MPa
0.4
~
0.6MPa
0.4
~
0.6MPa
Torch cooling mode
Air Cooling
Air Cooling / Water Cooling
Arc striking mode
HF
Insulation grade
F
Protection grade
IP21S
Dimension mm(L×W×H)
675×320×605
863×385×800
985×445×910
1015×445×910
NET WEIGHT
46kg
86 kg
129 kg
148 kg
4.2
Plasma gas condition
Gas pressure range
:
0.5MPa
~
0.7MPa
Gas supply pipe compression strength
:
≥1MPa
Gas supply pipe inner dimension
:
≥Φ8
Gas flow
:
≥180L/min
Filter the water in the gas, then feed into the plasma
4.3
External characteristic curve
Model
Parameters