User Manual
Rev 9.0
Page 31
HV Diagnostics
Steps
AS 1-AS 15
describe how to
configure a test sequence
.
Step
Procedure
(Configure Automatic Sequence)
Example
AS 1:
EDIT or NEW?
The “Edit Auto Test Seq”. Menu displays the
sequences already stored in memory.
•
To
modify
an existing program, highlight the
corresponding program from the list and select
the “EDIT” option, on the bottom of the screen
•
To
create
a new program, select the “NEW”
option, on the bottom of the screen
AS 2:
DUT
Select one of the following DUT types:
•
Cable
•
Motor
•
Generator
•
Transformer
•
Switchgear
•
Other
•
Vacuum Bottle
AS 3:
Voltage Rating
Specify the voltage rating of the DUT.
This is a characteristic of the DUT and does
NOT refer to the test voltage!
To increase / decrease the voltage rating, rotate
navigation knob (5).
To accept value, push in knob.
•
Min. rating = 0.1 kV, Max. rating = 50.0 kV
AS 4:
(Cables Only)
Insulation
Select one of the following cable insulation types:
•
XLPE
•
PILC
•
EPR
•
PE
•
PVC
•
HYBRID
(combination of types)
•
OTH. (other)
AS 5:
Test Purpose
Select aim of test from one the following:
•
Acceptance
•
Maintenance
•
Diagnostic
AS 6:
Waveform
Select one of the following output modes:
•
Sine wave
•
Square wave
•
DC+
•
DC-
•
Vacuum Bottle Test
AS 7:
Frequency
(Sinewave or
Squarewave only)
Set the frequency to as close to 0.1Hz as possible.
•
0.1 Hz/Auto: Recommended setting that
automatically maintains the frequency as close
to 0.1 Hz as possible
•
Permitted values: 0.01 - 0.1 Hz in 0.01 Hz
increments
Edit Auto Test Seq.
3.0kV Maint. C. HYBR (T)
BACK SELECT EDIT DEL
NEW
New Auto Test Seq.
What is the
Device under Test?
Cable
CANCEL
NEXT
New Auto Test Seq.
Cable
What is the
Voltage Rating of DUT?
1.0kV
CANCEL PREV
NEXT
New Auto Test Seq.
1.0kV Cable
What type of
Insulation?
XLPE
CANCEL PREV
NEXT
New Auto Test Seq.
1.0kV Cable XPLE
Test Function?
Maintenance
CANCEL PREV
NEXT
New Auto Test Seq.
1.0kV Cable XPLE
Maintenance
Waveform for Test?
Sine
CANCEL PREV
NEXT
New Auto Test Seq.
1.0kV Cable XPLE
Maintenance / Sine
Frequency for Test?
0.1Hz/ Auto
CANCEL PREV
NEXT