Hussmann DD5X5FRW Installation & Operation Manual Download Page 30

2-10 

e

lectrIcal

 / c

ontroller

 / W

ater

 / r

efrIgeratIon

P/N3053878_B

U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM

60

Remote Display Connection for Hussmann Case Display remote terminal (Vnr)

61

Remote Display Connection for Hussmann Case Display remote terminal (+)

62

Remote Display Connection for Hussmann Case Display remote terminal (-)

63

RS485 Slave

RS485 Slave connection (-) 

64

RS485 Slave

RS485 Slave connection (+)

65

LAN

LAN Connection (-) 

66

LAN

LAN Connection (+)

Network Connector 
Hussmann Controller Display, maximum 1 terminal per Core

L

ink

 

RS485 Slave connector 

Serial port (LAN or RS485)

First Power

The Corelink case controller requires roughly 45 

seconds to boot before any regulation will 

begin.  At the end of the boot cycle you will 

probably notice the case lights will illuminate 

and cases equipped with night curtains will 

open to the default position.

Micro-Distributed Operation 

The zones are controlled by a combination of 

Air Discharge 

sensors.  These sensors are used 

to regulate refrigeration around Se 

Deadband.   The average of those sensors will 

call compressors ON/OFF together. Additional 

time delays are incorporate to stage 

compressors.  

Application

All parameters are accessible from the 

controllers website or BAS system.  To review 

settings or make adjustments please refer to 

the connection methods listed in this manual.  

NO display is provided at the case unless opt.

Refrigeration 

Users can find typical settings in the 

refrigeration menu of website.  Case temp can 

be adjusted from here.  

Defrost

Corelink will manage defrost per its own defrost 

schedule or from external source such as BAS 

system for defrost coordination.  Users can find 

typical settings in the defrost menu of website. 

First Power

The CoreLink case controller requires roughly 
45 seconds to boot before any regulation will begin. 
At the end of  the boot cycle you will probably notice 
the case lights will illuminate and cases equipped with 
night curtains will open to the default position.

Micro-Distributed Operation 

The zones are controlled by a combination of  Air 
Discharge sensors. These sensors are used to regulate 
refrigeration around Se Deadband. The 
average of  those sensors will call compressors ON/OFF 
together. Additional time delays are incorporate to 
stage compressors. 

Application

All parameters are accessible from the controllers 
website or BAS system. To review settings or make 
adjustments please refer to the connection methods 
listed in this manual. 

NO display is provided at the case unless opt.

Refrigeration

 

Users can find typical settings in the refrigeration menu 
of  website. Case temp can be adjusted from here. 

Defrost

CoreLink will manage defrost per its own defrost 
schedule or from external source such as BAS system for 
defrost coordination. Users can find typical settings in 
the defrost menu of  website. 

Summary of Contents for DD5X5FRW

Page 1: ...flammable and heavier than air It collects first in low areas but can be circulated by the fans If propane gas is present or even suspected do not allow untrained personnel to attempt to find the cause The propane gas used in the unit has no odor The lack of smell does not indicate a lack of escaped gas If a leak is detected immediately evacuate all persons from the store and contact the local fire de...

Page 2: ...e to return to the store The propane gas used in the unit has no odor The lack of smell does not indicate a lack of escaped gas A hand held propane leak detector sniffer should be used before any repair and or maintenance is attempted All repair parts must be identical models to the ones they are replacing No open flames cigarettes or other possible sources of ignition should be used inside the bu...

Page 3: ...ne gas used in the unit has no odor The lack of smell does not indicate a lack of escaped gas If a leak is detected immediately evacuate all persons from the store and contact the local fire department to advise them that a pro pane leak has occurred Do not let any persons back into the store until the qualified service technician has arrived and that technician advises that it is safe to return t...

Page 4: ...mperatures Do not break the cold chain Keep products in freezer before loading into merchandiser These merchandisers are designed for only pre frozen products ATTENTION Merchandiser must operate for 24 hours before loading product Regularly check merchandiser temperatures Do not break the cold chain Keep products in freezer before loading into merchandiser Medium temperature merchandisers are desi...

Page 5: ...at Hussmann products will cause cancer or reproductive harm or is in violation of any product safety standards or requirements As clarified by the California State government Proposition 65 can be considered more of a right to know law than a pure product safety law When used as designed Hussmann believes that our products are not harmful We provide the Proposition 65 warning to stay in compliance...

Page 6: ...0 Cart Guide Installation 1 13 ELECTRICAL CONTROLLER WATER REFRIGERATION Electrical 2 2 Merchandiser Electrical Data 2 2 Plug 2 2 Main Disconnect Switch 2 3 Case Electronic Controller 2 4 Controller Troubleshooting 2 13 Refrigeration 2 14 Condensing Unit Access 2 14 Condensing Unit Views 2 15 Water For Condensers 2 16 Pre Installation System Cleaning 2 18 DRIP PIPING Waste Outlet and Water Seal 3 ...

Page 7: ...te air currents around the merchandisers To prevent sweating on the exterior surfaces of merchandisers there must be a minimum clearance of 3 inches 76 2 mm between the merchandisers and other fixtures or walls Product should always be maintained at proper temperature This means that from the time the product is received through storage preparation and display the temperature of the product must b...

Page 8: ... the lineup 2 Attach lifting straps to each lifting bracket 3 Remove the bolts attaching the case to the rider 4 Lift the case and move the rider out of the way 5 Lower the case to sit on the floor 6 Remove the lifting straps 7 Remove the end interior panels end interior back panels and bottom cover in order to prepare the case for joining Shipping Rider DETAIL A DETAIL B DETAIL C CENTER RIDER B A...

Page 9: ...om the highest point of the store floor Place shims under the rail and make sure that they are positioned at a base component crossbar This transfers the weight directly from the loaded case through to the floor Placing shims at other locations will cause uneven distribution of weight leading to piping leaks as well as sagging or wracked doors Bottom front supports must be shimmed if not in full c...

Page 10: ...ixtures Use the packaged hardware in the partition or joining kit Instructions are shipped with the partition kit All joints must be air tight to prevent formation of ice or condensation IMPORTANT Before installing the cases together at the end base uprights install the EPS insulation with the gasket onto the end base uprights Install the case joining bolts Run the case drain piping Reinstall the ...

Page 11: ...RACTERISTICS PER EPR 0006 IDENTIFIED WITH SYMBOL 3 MATERIAL 4 REF K SHEET 1 OF 12 P N REV THIRD ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES R REVISION HISTORY REV ECN DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY Door Base Plate Installation 18 Mark the holes for the door hinge plates in the door alignment guide share Pan Dur installation instructions with Jason Trevett...

Page 12: ...efthand lower cover using supplied painted screws 3 Install the lefthand upper cover 4 Install silicone sealant to gap and install trim piece 5 Repeat for righthand cover 6 Apply silicone sealant to joint of both roll in cases and install trim piece Lefthand Base Upright Cover Apply Sealant to Gap 1 1a 2 3 4 6 Insulation Piece Insulation Piece Installed Lower Cover Upper Cover Trim Piece Apply sea...

Page 13: ...038299 SCREW LOWERING HD 3X12 10 10 3038314 SCREW LOWERING HD 3X16 10 11 3038297 BOLT M8 X 30 5 12 3038296 BOLT M8 X 40 5 13 3038298 INSERT M8 CONCRETE 10 14 3037430 ASSEMBLY DOOR RH 3 15 3037431 ASSEMBLY DOOR LH 2 16 3037552 HANDLE DOOR 5 17 3048438 WIPER DOOR BOT CLR 366X25 98 5 18 3053841 DAMPENER DOOR DD5X5FRW 5 Door Assembly 14 15 17 USED ONLY IF NEEDED TO ADJUST DOOR HEIGHT LH DOOR ASSEMBLY ...

Page 14: ...y 14 15 1 18 16 6 17 3047086_C ITEM PART NUMBER TITLE QTY 1 3071389 BASE PLATE DOOR LH 2 2 3037440 COVER PIVOT BEARING LH 2 3 3037434 CAP 5 4 3073779 SWIVEL GUIDE DOOR LH 2 5 3037438 SPACER DOOR HEIGHT 10 6 3071390 BASE PLATE DOOR RH 3 7 3037439 COVER PIVOT BEARING RH 3 8 3073782 SWIVEL GUIDE DOOR RH 3 9 3038299 SCREW LOWERING HD 3X12 10 10 3038314 SCREW LOWERING HD 3X16 10 11 3038297 BOLT M8 X 30...

Page 15: ...DARDS SPECIFICATIONS ASME Y14 5M 1994 DIMENSIONS AND TOLERANCES 2 KEY PRODUCT CHARACTERISTICS PER EPR 0006 IDENTIFIED WITH SYMBOL 3 MATERIAL 4 REF K SHEET 1 OF 12 P N REV THIRD ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES R REVISION HISTORY REV ECN DATE REVISION DESCRIPTION REV BY CHKD BY APPR BY Door Base Plate Installation 18 Mark the holes for the door hinge plates in th...

Page 16: ... hinge base plate mounted into the concrete floor 4 Get the bottom door wipe in case packout Door wipe is to be installed onto bottom of the doors The glass wipes need to be put in the cooler prior to installation and trimming excess length 5 Locate the lefthand and righthand door hinge covers and remove the adhesive liner Mount hinge covers to the inside of the door Lineup lefthand hinge cover no...

Page 17: ...until it is aligned up with the bottom of the vertical door wipe The glass wipes need to be put in the cooler prior to installation and trimming excess length Door 1 handle side vertical door trim only Door 2 handle side vertical door trim and wipe Door 3 handle side vertical trim and wipe Door 4 handle side vertical trim and wipe Hinge side vertical door trim only Door 5 handle side vertical door...

Page 18: ...ass alignment is also affected with improper leveling of the merchandisers All steps of settting joining and case leveling attention to the glass position is critical Do not attempt to make glass adjustments prior to case leveling The bottom hinge plate can be modulated to assist in door alignment Location of the bottom hinge plate is shown on following page B Door Adjustment Remove the screws in ...

Page 19: ...OLERANCES DUCT CHARACTERISTICS PER EPR 0006 IDENTIFIED WITH SYMBOL L K SHEET 5 OF 11 P N THIRD ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES Cart Guide Installation 25 Place cart guide hole templates on the floor as shown in figure xxxx 26 Mark the holes and remove the cart guide hole template 27 Drill 3 8 diameter holes in the concrete 28 Place concrete anchors in the holes...

Page 20: ...ERANCES 2 KEY PRODUCT CHARACTERISTICS PER EPR 0006 IDENTIFIED WITH SYMBOL 3 MATERIAL 4 REF K SHEET 7 OF 12 P N REV THIRD ANGLE PROJECTION UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES K Bolt Locations Bolt Locations CART GUIDE INSTALLATION Continued 1 Place the cart guides on the floor Secure cart guides to floor using 1 4 inch washer and 1 4 inch bolt Bolts must be in center of slots Bolt L...

Page 21: ...ropane leak detector sniffer should be used before any repair and or maintenance is attempted All repair parts must be identical models to the ones they are replacing No open flames cigarettes or other possible sources of ignition should be used inside the building where the units are located until the qualified service technician and or local fire department determines that all propane has been clea...

Page 22: ...Disconnect power before servicing Merchandisers require a dedicated electrical circuit with ground 12AWG is the minimum sized acceptable wire for a 20 amp circuit 10 AWG for a 30 amp circuit The DD5X5FRW W requires a dedicated 50 amp 125V circuit with a grounded wall receptacle NEMA L5 50P Always use a dedicated circuit with the amperage stated on the unit Plug into an outlet designed for the plug...

Page 23: ...The switch is positioned towards the back of the case The following image shows the disconnect switch The disconnect switch must be turned OFF before servicing the merchandiser s All the electrical connections are to be made in the electrical box located on top of the case at the right side It is the installing contractor s responsibility to consult local agencies for local code requirements Merch...

Page 24: ...When using the digital inputs of the CoreLink CaseControlleruseanothertransformerinorder to preventthedigitalinputsfrom malfunctioning or being damaged To avoid causing static discharge do not touch the electronic components on the boards DO NOT use the same secondary of the controllers power Doingso can resultin damagetocasecontroller DO NOT exceed the maximum current capacity of the onboard cont...

Page 25: ...wo methods for accessing CoreLink The wireless connection kit directly at the CoreLink hosted byWeb UI on a connected smart device or users can use BuildingAutomated System BAS to change parameters from a single central location For explanation of wireless connection at the case consult the CoreLink user manual underWeb User Interface Section Defrost is time initiated and is programmed with the co...

Page 26: ...alytics web user interface CSV format with 15 critical data points Onboard data logging allows user to review performance data from the past week User can see Min Max Average data along with saving data sets and importing data sets for view Factory Restore The CoreLink application has a configuration file with the complete and optimized default case settings Anytime a user wants to default to fact...

Page 27: ... 10 secs Illuminated Solid ON 30 secs Reboot See Boot Sequence Programming Sequence USB Flash Drive Yellow Status LED Time Off 5 secs Dim 10 secs Illuminated Solid ON 30 secs Blinking Normal Operation Indefinitely Boot Sequence Power Indicator Green LED Status Yellow LED Bios Version 2017011600 Web UI Version 1 3 0 Application Version 2 0 0 Controller Label LED Indicators ...

Page 28: ...GND Network Connector Hussmann Controller Display maximum 1 terminal per CoreLink RS485 Slave connector Serial port LAN or RS485 USB port for downloads BIOS application configuration files remote display applications network configurations website and uploads log files Connection with the computer via a USB ETHERNET converter Connection with wireless connection kit Digital relay outputs 4 NO relay...

Page 29: ... Connector for 24Vac dc power supply Analogue inputs Pb1 Pb6 Pbc Additional Power 5Vdc 12Vdc GND Analogue outputs Out1 Out4 GND 24Vac dc digital inputs DI1 DI11 GND Note Not a dry contact switch power supply 24Vac or 24Vdc required to activate switch If using 24Vdc pin 31 is GND 20 DI1 Digital input 24Vac dc 21 DI2 Digital input 24Vac dc 22 DI3 Digital input 24Vac dc 23 DI4 Digital input 24Vac dc ...

Page 30: ...on methods listed in this manual NO display is provided at the case unless opt Refrigeration Users can find typical settings in the refrigeration menu of website Case temp can be adjusted from here Defrost Corelink will manage defrost per its own defrost schedule or from external source such as BAS system for defrost coordination Users can find typical settings in the defrost menu of website First...

Page 31: ...Roll In P N 3053878_B 2 11 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A ...

Page 32: ...2 12 Electrical Controller Water Refrigeration P N3053878_B U S Canada 1 800 922 1919 Mexico 1 800 890 2900 WWW HUSSMANN COM ...

Page 33: ...Roll In P N 3053878_B 2 13 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A CONTROLLER TROUBLESHOOTING ...

Page 34: ...refrigerant charge information The following illustration shows the details of the refrigeration system CONDENSING UNIT ACCESS Condensing units are located on top of the case The condensing unit s have an electrical box for wire connections and field service All the cases and condensing units electrical connections are done at the factory Attention trained service personnel Mandatory safety servic...

Page 35: ...Roll In P N 3053878_B 2 15 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A CONDENSING UNIT VIEWS ...

Page 36: ...r flow requirements for each case are 5 Door 4 Gallons per Minute GPM Auto balance valves are provided The inlet and outlet water connections are attached using a 3 4 inch adapter Use clamps not supplied to tighten the hoses in place There are hand valves for system isolation located on the inlet and outlet water connections The hand valves hose adapter and their locations on the case are shown on...

Page 37: ...NSOR ONLY TOP PANEL THERMOMETER HOLE B B A DETAIL A TOP LEFT SIDE OF CASE 1 50 APPROX 1 50 APPROX VIEW OF TOP OF CASE HACCP SENSOR TOP LEFT DEFLECTOR ONLY GETS 3 SENSORS SEE DETAIL A DISCHARGE AIR SENSOR ONLY DISCHARG DEFLECTOR DISCHARGE OPTIONAL SOLAR THERMOMETER ATTACH SENSORS TO UNDERSIDE OF DEFLECTOR DISCHARGE AS SHOWN LOOKING AT TOP FRONT LEFT SIDE OF CASE LEFT SIDE OF CASE TOP PANEL THERMOME...

Page 38: ...n contractor must consult and be familiar with the manufacturer s Material Safety Data Sheets MSDS before handling any secondary fluid The MSDS contains proper disposal and safety methods Automatic Balancing Valves Case may be equipped with automatic balancing valves Thecasewillmaintainthecorrectflowrate Thecooling system pressure must be between 5 to 30 psig for proper operation of the automatic ...

Page 39: ...ies will cause an air lock and prevent draining Pitch the drip piping in the direction of flow There should be a minimum pitch of 1 4 in per ft 20 mm per 1 m Avoid long runs of drip piping Long runs make it impossible to provide the pitch necessary for good drainage Provide a suitable air break between flood rim of the floor drain and outlet of drip pipe To meet code on low base merchandisers it m...

Page 40: ...d 2 between the top of the water seal outlet and the bottom of the merchandiser Do not over rotate or gravity seal may be compromised Always rotate trap bottom toward merchandiser support rail 1 2in Clearance to Floor Approx Factory Installed Tee Fitting Factory Installed four turns Do NOT use Thread Sealer on Drain Fitting Drain Fitting Rotate Water Seal towards back of Merchandiser if required C...

Page 41: ...ed drip piping may require additional support depending on the number and location of the hub floor drains The installer should always provide adequate support to all drip piping arrangements to prevent excess stress on all drip piping components The installer must provide additional support when evac type waste water systems are applied It is the installing contractor s responsibility to consult ...

Page 42: ...3 4 Drip Piping P N 3053878_B U S Canada 1 800 922 1919 Mexico 1 800 890 2900 WWW HUSSMANN COM NOTES ...

Page 43: ...ervice technician and or local fire department determines that all propane has been cleared from the area and from the refrigeration systems 12 HOURS AFTER STARTUP CHECKLIST Check case temperature Check if there is any CoreLink alarm Check water connections for leaks or accumulation of water Verify the fans are running Check compressor s amperage and validate with the information on serial plate C...

Page 44: ... to check the current to each compressor CHECK each fan to ensure it is running The discharge air output at the top inside front of the case honeycomb area should be relatively even across the length of the case VERIFY there are no leaks at connections for the condenser water STARTUP AND OPERATION See the merchandiser s Technical Data Sheet for refrigerant settings and defrost require ments Bring ...

Page 45: ...apply to display refrigerators intended for bulk produce refer to Page 1 1 Please note that the tape cannot be exposed after installation This is an NSF 7 US FDA Food Code Required Thermometer Suggested Mounting Locations in Single Deck Glass Front Impact Merchandisers Acrylic Package Guard Facing Out Inside End Panel Shelf Price Tag Molding Return Air Grille Suggested Mounting Locations in Multi ...

Page 46: ...above The thermometer may need to be moved several times to find the warmest location Mounting options include flexible plastic for price tag molding application magnet applied to back of flexible plastic for steel end wall and double stick tape Tape must not be exposed after installation Questions about either code should be addressed to local agencies or other appropriate officials Important Ple...

Page 47: ...paper towels on coated glass Ammonia based cleaners on acrylic parts Solvent oil or acidic based cleaners on any interior surfaces Do Use Remove the product and all loose debris to avoid clogging the waste outlet Store product in a refrigerated area such as a freezer Remove only as much product as can be taken to the freezer in a timely manner First turn off refrigeration then disconnect electrica...

Page 48: ... solution may be used periodically to minimize scratching and remove stains Rinse and wipe dry immediately after cleaning Never use hydrochloric acid muriatic acid on stainless steel CLEANING COILS NEVER USE SHARP OBJECTSAROUND COILS Use a soft brush or vacuum brush to clean debris from coils Do not puncture coils Do not bend fins Contact an authorized service technician if a coil is punctured cra...

Page 49: ... place The safety procedure must comply with all applicable codes such as local fire department s codes At minimum the following actions are required Immediately evacuate all persons from the store and contact the local fire department to advise them that a propane leak has occurred Call Hussmann and or a qualified service agent and inform them that a propane sensor has detected the presence of propa...

Page 50: ...ly For access to these fans 1 Turn off power 2 Remove interior top and back panels 3 Disconnect fan from wiring harness 4 Remove screws holding fan motor bracket assembly to plenum and remove assembly 5 Replace fan motor bracket assembly and reinstall screws 6 Reconnect fan to wiring harness 7 Turn on power 8 Verify that motor is working and blade is turning in the correct direction 9 Replace inte...

Page 51: ...r manufacturer This includes the glass doors door frame assemblies LED lighting hold open slides and power cords Refer to specific warranty supplied with the door The manufacturers have a warranty against moisture penetration a warranty against tempered glass breakage and a warranty on power supplies Lamps are not covered by Hussmann or the door manufacturer Replace LED fixtures with like fixtures...

Page 52: ...gon 1570 E Northgate P O Box 2102 Irving TX 75062 Phone 1 800 527 9916 NOTE Hussmann Aluminum melts at 1125 F 607 C Aladdin 3 in 1 rod at 732 F 389 C X Ergon Acid core at 455 F 235 C Technique 1 Locate Leak 2 REMOVE ALL PRESSURE 3 Brush area UNDER HEAT 4 Use PRESTOLITE TORCH ONLY Number 6 tip 5 Maintain separate set of stainless steel brushes and USE ONLY ON ALUMINUM 6 Tin surface around area 7 Br...

Page 53: ... the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044 2483 01 October 2012 To obtain warranty information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044 2483 01 October 2012 ...

Page 54: ...6 6 Hussmann Corporation 12999 St Charles Rock Road Bridgeton MO 63044 2483 www hussmann com ...

Reviews: