CASE JOINING
Sectional construction means that two or more
merchandisers may be joined in line yielding one long
continuous display requiring only one pair of ends.
Joining kits and instructions are shipped with each
merchandiser. A partition kit is required to join unlike
fixtures. Use the packaged hardware in the partition
or “joining kit”. Instructions are shipped with the
partition kit.
a
ll
joinTs
musT
be
air
-
TighT
To
prevenT
formaTion
of
ice
or
condensaTion
.
IMPORTANT:
Before installing the cases together at the end base
uprights, install the EPS insulation with the gasket
onto the end base uprights.
Install the case joining bolts. Run the case drain piping.
Reinstall the bottom back cover, interior back
panels and top panels.
Joining Locations
1½ x ½ inch
Gasket
1 ½ x ½ inch
Gasket
1½ x ½ inch
Gasket
Apply a bead of
silicone sealant
along joining
surface
Case joining covers are located behind interior back panels.
Front View of Case
Case Joining