9
SHOCK ABSORBER, SWINGARM
66
Pressure
•
Vacuum
Equallza
pressure
When the pressure gauge reaches the specified value, turn the
Oil reservoir
0
control lever to
Vacuum.
Guideline
0 bar
✓ The vacuum gauge falls to the specified value.
8 mbar
When the vacuum pressure gauge reaches the specified value, turn the
Oil reser
voir
control lever
0
to Equalize Pressure.
Guideline
8 mbar
✓ The pressure gauge drops to the specified value.
0 bar
When the pressure gauge reaches the specified value, turn the
Damper
control
lever
C,
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the specified value.
3 bar
When the pressure gauge reaches the specified value, turn the
Damper
C,
con
trol lever to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the specified value.
0 bar
When the pressure gauge reaches the specified value, operate the
On/Off
switch.
Guideline
0 bar
✓ The vacuum pump is switched off.
Slide O-ring
0
to the end of the special tool by the specified value (distance
6)
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
�
p. 235)
Slide the floating piston into the reservoir to the shortened position using the spe
cial tool.
•
Info
I
The floating piston must be positioned at exactly this point when the rod
is fully extended; otherwise, damage will occur during compression of the
shock absorber.
Remove the special tool.