6
6.26
FORK, TRIPLE CLAMP
36
200889-10
200890-10
- Disconnect the vacuum pump. Remove the special tool.
•
Info
I
The filling port must be positioned at the highest point.
Mount and tighten the filling screw with the O-ring.
Guideline
I
Cartridge filling screw
I
M4x0.5
I 2 Nm (1.5 lbf ft)
- Clamp the cartridge in a vise using soft jaws.
•
Info
I
Clamp the cartridge only lightly.
- Connect the connector of the special tool to the pressure regulator of the nitrogen
bottle.
Nitrogen charging tool (T14019) (
�
p. 238)
Filling gas - nitrogen
- Adjust the pressure regulator of the nitrogen bottle.
Guideline
I
Gas pressure
11.2 bar (17 psi)
- Pierce the membrane with the needle of the special tool.
- Open valve
O.
- Fill the cartridge for at least 15 seconds.
Guideline
I
Gas pressure
•
Info
I
Watch the pressure regulator dial.
11 .2 bar (1 7 psi)
Ensure that the cartridge is filled to the specified pressure.
- Close the valve.
- Close the nitrogen bottle.
- Remove the special tool.
- Mount and tighten filling screw
8
with the O-ring.
Guideline
Nitrogen filling screw of the fork leg
M4x0.5
2.5 Nm
(1.84 lbf ft)
Greasing the steering head bearing
�
,�,
:�:·
:-
.... -.. -·
�
!�i
s
800010-10
- Remove the lower triple clamp. (
�
p. 37)
- Install the lower triple clamp. (
�
p. 37)