9
SHOCK ABSORBER, SWINGARM
65
Info
Clamp the damper only lightly.
The filling port must be at the highest point.
The piston rod slides in and out during filling - do not hold it tight with your
hand!
Clamp the control lever as shown in the figure.
✓ The
External tank
fD
control lever is on
Closed, Damper
8
on Vacuum,
and
Oil reservoir
0
on Vacuum.
Operate the
On/Off
switch Q).
✓ The vacuum pump process starts.
✓ Pressure gauge @ drops to the specified value.
< 0 bar
✓ The vacuum gauge
C,
falls to the specified value.
4 mbar
Measure distance
f)
between the floating piston and reservoir hole with the spe
cial tool.
I
Depth micrometer (T107S) (
0
p. 235)
✓ The floating piston is positioned all the way at the bottom.
When the vacuum pressure gauge reaches the specified value, turn the
Oil reser
voir
control lever
0
to Equalize pressure.
Guideline
4 mbar
✓ The pressure gauge increases to the specified value.
0 bar
When the pressure gauge reaches the specified value, turn the
Damper
control
lever
8
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the specified value.
3 bar
When the pressure gauge reaches the specified value, turn the
Damper
8
con
trol lever to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the specified value.
0 bar