6
FORK, TRIPLE CLAMP
36
200889-10
When the vacuum gauge reaches the required value, turn control lever
Oil reser
voir
0
to
Equalize pressure.
Guideline
10 mbar
✓ The pressure gauge increases to the required value.
0 bar
When the pressure gauge reaches the required value, turn control lever
Damper
C,
to
Pressure.
Guideline
0 bar
✓ Oil is pumped into the cartridge.
✓ The pressure gauge increases to the required value.
3 bar
When the pressure gauge reaches the required value, turn control lever
Damper
C,
to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, activate the
On/Off
switch.
Guideline
0 bar
✓ The vacuum pump is switched off.
Disconnect the vacuum pump. Remove the special tool.
•
Info
I
The filling port must be positioned at the highest point.
Mount and tighten the filling screw with the O-ring.
Guideline
I
Cartridge filling screw
M4x0.5
I 2 Nm (1.5 lbf ft)
e with nitro en
200890-10
Clamp the cartridge in a vise using soft jaws.
•
Info
I
Clamp the cartridge only lightly.
Connect the connector of the special tool to the pressure regulator of the nitrogen
bottle.
Nitrogen charging tool (T14019) ("" p. 231)
Filling gas - nitrogen
Adjust the pressure regulator of the nitrogen bottle.
Guideline
I
Gas pressure
1.2 bar (17 psi)
Pierce the membrane with the needle of the special tool.
Open valve
O.
Summary of Contents for FC 350 2014
Page 1: ...PIONEERING SINCE 1903 REPAIR MANUAL2014 FC 350 EU Art no 3403006en Husqvarna MOTORCYCLES ...
Page 2: ......
Page 90: ...12 FUEL TANK SEAT TRIM Start the motor and check the response 88 ...
Page 192: ...18 CLUTCH 190 Position the cover with the membrane Mount and tighten the screws ...
Page 236: ...30 SPECIAL TOOLS 234 Nitro en filling tool Art no T170S1 2x 3x T170S1 H00855 01 ...