background image

Portable Air
Compressors

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Portable permanently lubricated air
compressors are for home and
workshop use. All models are equipped
with regulators, needle and ball
bearings, and motors with automatic
overload protection. Draining moisture
from the air receivers is required
maintenance. 

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols. 

Danger indicates 
an imminently

hazardous situation which, if not
avoided, will result in death or serious
injury.

Warning indicates 
a potentially

hazardous situation which, if not
avoided, could result in death or
serious injury.

Caution indicates a 
potentially

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates 

important

information, that if not followed, may
cause damage to equipment.

Unpacking

When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service.

NOTICE

!

CAUTION

!

WARNING

!

DANGER

Operating Instructions   

FP2021

Breathable Air Warning

This compressor/pump is not
equipped and should not be used
“as is” to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment. This
additional equipment is
necessary to properly filter and
purify the air to meet minimal
specifications for Grade D
breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not simultaneously
used, existing warranties shall be
voided, and Husky disclaims any
liability whatsoever for any loss,
personal injury or damage.

!

DANGER

Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up a
high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.

All electrical work 
should be done by a

qualified (licensed or certified)
electrician. On a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.

1. Read instruction manuals for each

component carefully, before
attempting to assemble,
disassemble or operate your
particular system.

2. Do not exceed pressure rating of

any component in system.

3. Protect material lines and air lines

from damage or puncture. Keep
hose and power cord away from
sharp objects, chemical spills, oil,
solvents, and wet floors.

4. Never point a spray gun at oneself

or any other person. Accidental
discharge may result in serious
injury.

5. Check hoses for weak or worn

condition, before each use, making
certain all connections are secure;
do not use if deficiency is found.
Notify an authorized service facility
for examination or repair.

!

WARNING

IN605000AV 3/02

General Safety 

Description

6. Release all pressures within system

slowly; dust and debris may be
harmful.

Disconnect power 
and depressurize

system before servicing air compressor!
(Turn pressure regulator knob fully
clockwise after shutting off
compressor).

!

WARNING

Portable Air Compressors
Compresseurs d’Air Portatifs 
Compresores de Aire Portátiles  

Notes

Notas

FP2021

www.chpower.com

Summary of Contents for FP2021

Page 1: ...for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DISCLAIMER OF WARRANTIES In the eve...

Page 2: ...comprador original tal como se especifica a continuaci n Productos Est ndard Standard Duty Un a o 2 QUIEN OTORGA ESTA GARANTIA EL GARANTE Campbell Hausfeld The Scott Fetzer Company 100 Production Dri...

Page 3: ...ted by ring it MUST be replaced REGULATOR KNOB 1 This knob controls air pressure to an air operated tool or paint spray gun 2 Turning knob clockwise increases air pressure at outlet 3 Turning counterc...

Page 4: ...ire or length of extension cord 3 Shorted or open motor winding 4 Defective check valve or unloader 1 Check for proper use of extension cord see EXTENSION CORDS page 3 2 Plugged in Check fuse breaker...

Page 5: ...un compresor que no requiere lubricaci n adicional PROTECTOR TERMICO Esta com presora est equipada con un protector de sobrecarga t rmica de reposici n autom tica Si el protector t rmico apaga al com...

Page 6: ...OF THE CAMPBELL HAUSFELD PRODUCT Some States do not allow the exclusion or limitations of incidental or consequential damages so the above limitation or exclusion may not apply to you C Any failure th...

Page 7: ...motores el ctricos deben asegurarse bien y estar conectados a tierra adecuadamente Vea las instrucciones para conectar a tierra y la informaci n sobre cordones de extensi n en este manual 10 Siempre...

Page 8: ...verte et l tiquetter pour viter une application de puissance inattendue 11 Prot ger contre les pi ces mobiles garder les visiteurs l cart de l endroit de travail Ne jamais permettre les enfants dans l...

Page 9: ...ati re et de fabrication consid rables avec les exceptions indiqu es ci dessous 6 LA PR SENTE GARANTIE NE COUVRE PAS A Les garanties implicites y compris celles de commercialisabilit et D ADAPTION UNE...

Page 10: ...r servoir 1 Purger le r servoir 2 D m nager un endroit moins humide utiliser un filtre en canalisation d air 1 Apportez le compresseur chez un centre de service 2 Diminuer la consommation d air le com...

Page 11: ...r servoir 1 Purger le r servoir 2 D m nager un endroit moins humide utiliser un filtre en canalisation d air 1 Apportez le compresseur chez un centre de service 2 Diminuer la consommation d air le com...

Page 12: ...ati re et de fabrication consid rables avec les exceptions indiqu es ci dessous 6 LA PR SENTE GARANTIE NE COUVRE PAS A Les garanties implicites y compris celles de commercialisabilit et D ADAPTION UNE...

Page 13: ...verte et l tiquetter pour viter une application de puissance inattendue 11 Prot ger contre les pi ces mobiles garder les visiteurs l cart de l endroit de travail Ne jamais permettre les enfants dans l...

Page 14: ...motores el ctricos deben asegurarse bien y estar conectados a tierra adecuadamente Vea las instrucciones para conectar a tierra y la informaci n sobre cordones de extensi n en este manual 10 Siempre...

Page 15: ...OF THE CAMPBELL HAUSFELD PRODUCT Some States do not allow the exclusion or limitations of incidental or consequential damages so the above limitation or exclusion may not apply to you C Any failure th...

Page 16: ...un compresor que no requiere lubricaci n adicional PROTECTOR TERMICO Esta com presora est equipada con un protector de sobrecarga t rmica de reposici n autom tica Si el protector t rmico apaga al com...

Page 17: ...ire or length of extension cord 3 Shorted or open motor winding 4 Defective check valve or unloader 1 Check for proper use of extension cord see EXTENSION CORDS page 3 2 Plugged in Check fuse breaker...

Page 18: ...ted by ring it MUST be replaced REGULATOR KNOB 1 This knob controls air pressure to an air operated tool or paint spray gun 2 Turning knob clockwise increases air pressure at outlet 3 Turning counterc...

Page 19: ...comprador original tal como se especifica a continuaci n Productos Est ndard Standard Duty Un a o 2 QUIEN OTORGA ESTA GARANTIA EL GARANTE Campbell Hausfeld The Scott Fetzer Company 100 Production Dri...