![Hunter ACC2 Quick Start Manual Download Page 54](http://html.mh-extra.com/html/hunter/acc2/acc2_quick-start-manual_2184727054.webp)
54
hunter.direct/ACC2help
Decoders Menu
PROGRAMMING SENSOR DECODERS
The ICD-SEN is a unique decoder for connecting sensor inputs
via the two-wire path. If a sensor decoder is connected to the
programming port, it will be detected and shown as a Decoder
Type: Sensor, with its own screen.
The address number is the only item to set. Sensor decoders
can be addressed from one to nine (the maximum possible
number of sensor decoders). These are not the same as
station addresses, and they do not subtract from or conflict
with station addresses.
Select the sensor decoder address, and press the Program
Decoder soft key to program the decoder. Mark the decoder
and install at the sensor location.
PROGRAMMING DECODERS VIA THE TWO-WIRE PATH
In addition to the Programming Port selection, it is possible to
re-program any installed decoder via the two-wire path.
For this option to be used, the decoder must already be
programmed and installed in the two-wire path.
At the Program Decoder screen, check the box for 2-Wire
Path instead of Programming Port.
The menu will now allow selection of Station, Pump, or Sensor
decoder types. Select the type of decoder to re-program,
then enter the address. Press Read Decoder to get the current
setup for item you selected, then enter the changes. Press
Program Decoder to send the changes down the two-wire
path to the selected decoder.