![Hunter ACC2 Quick Start Manual Download Page 53](http://html.mh-extra.com/html/hunter/acc2/acc2_quick-start-manual_2184727053.webp)
Built on Innovation
®
53
Decoders Menu
PROGRAMMING STATION DECODERS
To program station decoders, dial to the first station number,
select, and enter the station number for the first station
output. Dial to each station output in multi-station decoders
and enter the station number for each output.
You may enter any station numbers in any order. You may also
leave outputs blank, for future expansion. Blank outputs will
not operate until a station number is entered, but all other
stations will function normally.
When the station outputs are all entered, press the
Program Decoder soft key. After a brief pause, the message
“Programming Decoder Successful!” should appear. Remove
the decoder, and write the numbers on the decoder label with
a permanent marker. Install the decoder at the appropriate
valve location.
PROGRAMMING PUMP/MASTER VALVE (PMV) DECODERS
Only single-station ICD-100 decoders should be used as P/MV
decoders, since other station outputs will be wasted.
Insert the station wires in the programming port, press Read
Decoder, and wait for the decoder information to appear.
Press the soft key labeled Pump Decoder.
Enter the P/MV number for the decoder. This must match the
P/MV assignment in the Devices menu.
Press the Program Decoder soft key, and mark the P/MV
number on the decoder. Install the decoder at the pump or
master valve location.