6

Update Software

Install the MEGA 360 ICE Mount

Use the following instructions to install the MEGA 360 Imaging ICE transducer 
mount. It is important to read the instructions completely and understand the 
mounting guidelines before you start the installation.

1. Prepare for Installation

1.  Supplies: Philips screwdriver.
2.  Complete the ICE HELIX Series Shuttle installation before proceeding with 

this installation.

3.  When the transducer pod is in use, the pod should be completely submerged 

below the ice. The transducer pod should not have anything obstructing 
the ‘view’ of the rotating beams. If the beams are blocked, confirm that the 
transducer is below the ice and move other equipment, such as additional 
transducers, if possible. 

2. Install the MEGA 360 ICE Mount Base

Use the following instructions to install the MEGA 360 ICE mounting assembly:

1.  Slide the cam lock over the MEGA 360 cables and down the pod shaft. 
2.  Determine the desired height for the ice base, depending on the thickness of 

the ice, and close the lever arm to lock the cam lock into position. 

   

NOTE:

 The MEGA 360 pod must be submerged below the ice.

3.  From the bottom of the ice base, insert the round, black bushing into the 

center of the base. You will hear it snap into place. 

4.  From the top of the ice base, line up the collet with the keyed grooves in the 

base and slide it into place. 

Update Software with FishSmart

You can use the FishSmart App to download and push software updates directly to 
your Humminbird control head or accessory. 

NOTE:

 Your control head must already be running software release 1.610 and later 

to support this feature.

NOTE:

 You must first download the FishSmart App and pair your mobile device to 

your control head. See the 

FishSmart User Manual 

for more information.

1.  Open the FishSmart App on your mobile device.

2. 

Apple iOS: 

Tap the System menu icon.

Google Android:

 Tap the FishSmart main menu. Select system.

3.  Tap Update next to the selected unit. The download progress is displayed on 

the screen.

4.  Tap Transfer next to the selected unit once the download is complete.

5.  Confirm the estimated transfer time.

6.  Tap the checkbox to select where to upload the software update (internal 

storage, card slot 1, or card slot 2).

7.  Tap Transfer. The upload progress is displayed on the System menu in 

FishSmart and in the System Status view on the control head. 

8.  Follow the on-screen prompts on the control head to complete the software 

installation.

Summary of Contents for MEGA 360 ICE ADAPTER

Page 1: ...1 MEGA 360 ICE INSTALLATION GUIDE 532856 1EN_A...

Page 2: ...merged objects WARNING The electronic chart in your Humminbird unit is an aid to navigation designed to facilitate the use of authorized government charts not to replace them Only official government...

Page 3: ...rrect translations or discrepancies between documents NOTE Product specifications and features are subject to change without notice NOTE Humminbird verifies maximum stated depth in saltwater condition...

Page 4: ...the MEGA 360 ICE Mount Base 7 3 Install the Handle 9 4 Install the Heading Sensor 10 Route the Cables and Connect Power 12 Set Up the Control Head 14 1 Confirm Connections 14 2 Set Up the Transducer 1...

Page 5: ...8 19 20 21 21 21 Transducer Maintenance 22 Troubleshooting 23 Fishing System Doesn t Power Up 23 Fishing System Defaults to Simulator with a Transducer Attached 24 Finding the Cause of Noise 25 Specif...

Page 6: ...iii Intr The 360 insta Com Con cont Tran tran...

Page 7: ...talled Refer to the ICE HELIX Shuttle Installation Guide for more information Compatibility Control Heads MEGA360ICEImagingiscompatiblewiththefollowingHumminbird control heads HELIX MEGA Imaging G3N a...

Page 8: ...cer splitter cable y cable and a heading sensor quick disconnect cable Accessories For the most current list of compatible accessories visit our Web site at humminbird com Supplies In addition to the...

Page 9: ...on completely before starting any software updates Software Requirements HELIX Series 2 180 and later Check the Current Software Version It is helpful to review the software version number that is cur...

Page 10: ...nstall a formatted SD or microSD card into the computer card slot 3 Go to humminbird com and click Support Software Updates 4 Click on your control head model The available software updates are listed...

Page 11: ...ollow the on screen prompts to save the software file to the SD or microSD card 4 Power on your Humminbird control head Start Normal mode 5 Insert the SD or microSD card with the software file into th...

Page 12: ...1 Open the FishSmart App on your mobile device 2 Apple iOS Tap the System menu icon Google Android Tap the FishSmart main menu Select system 3 Tap Update next to the selected unit The download progres...

Page 13: ...If the beams are blocked confirm that the transducer is below the ice and move other equipment such as additional transducers if possible 2 Install the MEGA 360 ICE Mount Base Use the following instr...

Page 14: ...bling the Base 5 Thread the MEGA 360 cables up through the ice base and slide the ice base down the pod shaft It will rest on the cam lock 6 Thread the MEGA 360 cables up through the knob and slide th...

Page 15: ...e depth collar 2 Thread the MEGA 360 cables up through the depth collar and slide the depth collar down the shaft to the desired height 3 Place the bolt through the counterbore hole in the depth colla...

Page 16: ...heading sensor mount with one 1 4 20 screw and one 1 4 20 hex nut through the stem 5 Route the MEGA 360 cables through the opening of the heading sensor mount and hold them in place 6 Position the se...

Page 17: ...11 Installing the ICE Mount Fully Assembled MEGA 360 ICE back 20 nsor nt of ews ings...

Page 18: ...te the MEGA 360 ICE sonar Y cable and heading sensor quick disconnect cable to the HELIX cable tray See the ICE HELIX Installation Guide for more information about routing cables to the cable tray NOT...

Page 19: ...o the heading sensor quick disconnect cable 6 Cable Management Wrap excess cable using the molded hooks on the MEGA 360 ICE adapter base NOTE The connectors are keyed to prevent reversed installation...

Page 20: ...n on the power source from the main switch 2 On the control head press the POWER key If you are powering on a control head in a multiple control head Ethernet network power on the control head that is...

Page 21: ...set up your HELIX control head with a new transducer 1 Main Menu Press the Menu key twice 2 Select the Sonar tab Connected Transducer 3 Press the RIGHT or LEFT Cursor keys to scroll through the compa...

Page 22: ...View 3 The sonar returns from the MEGA 360 scan will begin to display on the MEGA 360 View Review the display for the following information and see the illustration Reviewing the 360 View Bottom Confi...

Page 23: ...d hold the VIEW key Select Chart Chart View 8 With a Chart View displayed on screen rotate your transducer assembly so that it is pointing at a known object on the horizon like land and compare the He...

Page 24: ...observe in the environment around you use 360 Heading Offset to correct the alignment of the MEGA 360 Imaging display For example if there is an object in the water that is displayed on the left side...

Page 25: ...up the Network After you have confirmed all connections the MEGA 360 Imaging transducer is ready to use on the water Proceed to your MEGA 360 Operations Manual to set up the depth source temperature s...

Page 26: ...enu 1 With a 360 View or 360 Imaging Combo View displayed onthe screen press the MENU key once 2 Select 360 Pinging and press the LEFT Cursor key to select Off Stop Pinging from the Power Submenu 1 Pr...

Page 27: ...e shaft Check for ice buildup periodically and remove it as needed Control Head Maintenance It is important to consider the following precautions when using your Humminbird control head Chemicals such...

Page 28: ...ion If your transducer remains in the water for long periods of time ice can accumulate around the shaft Check for ice buildup periodically and remove it as needed Periodically clean the face of the t...

Page 29: ...the installation guide that is included with your Fishing System to confirm specific details making sure that the power cable is properly connected to the Fishing System control head the power cable i...

Page 30: ...eans that the control head is not detecting the transducer Perform the following troubleshooting tasks Check the connections of all transducers that are connected to the control head or Ethernet netwo...

Page 31: ...e Possible Source of Noise Isolation Other electronic devices Turn off any nearby electronic devices to see if the problem goes away then turn them on one at a time to see if the noise re appears Othe...

Page 32: ...S 4000 Watts Peak to Peak Power Requirement 10 to 18 VDC Current Draw 0 5 A maximum Operating Temperature 4 F to 158 F 20 C to 70 C Storage Temperature 40 F to 158 F 40 C to 70 C NOTE Humminbird verif...

Page 33: ...oduct life cycle WEEE compliance may not be required in your location for electrical electronic equipment EEE nor may it be required for EEE designed and intended as fixed or temporary installation in...

Page 34: ...humminbird com Telephone 1 800 633 1468 Direct Shipping Humminbird Service Department 678 Humminbird Lane Eufaula AL 36027 USA Hours of Operation Monday Friday 8 00 a m to 4 30 p m Central Standard T...