![Hughes JVC 100 Service Manual Download Page 90](http://html1.mh-extra.com/html/hughes-jvc/100/100_service-manual_2182203090.webp)
Chapter 4---Maintenance (Removal/Replacement)
Model 100 Service Manual
filters should be cleaned more frequently. To clean the filters, remove, vacuum
out or blow the filters with compressed air.
!
One filter is a foam filter located in the rear of the projector.
!
The other filter is located on the on the bottom left side of the projector,
just in front of the HVPS.
Figure 4-3
Air Filter (bottom left side).
4.4 Arc Lamp Assembly
The Arc Lamp Assembly consists of a Xenon Arc Lamp, a Docking Module, a
light shield and an Arc Lamp cooling duct. The Arc Lamp fits inside the Docking
Module.
CAUTION!:
It is strongly recommended that the Arc Lamp
current be turned down (see Section 3.1) before installing a new Arc
Lamp to help prevent possible damage that could reduce the life of the
new lamp.
WARNING!!!
Dangerous light exists in this area of the
projector. Before proceeding with the removal of any subassemblies
below, always:
!
Turn the projector off, allow the projector to cool for 5 minutes.
!
Power off the main ac circuit breaker at the front right corner of the
projector
!
Remove the power plug from the AC outlet.
To remove the Arc Lamp Docking Module: