![Hughes JVC 100 Service Manual Download Page 101](http://html1.mh-extra.com/html/hughes-jvc/100/100_service-manual_2182203101.webp)
Chapter 4---Maintenance (Removal/Replacement)
4-16
Model 100 Service Manual
NOTE:
The connectors CN107, CN108, and CN109 are found on the
Video Amplifier PCB respective to the CRT/ ILA
®
being replaced.
2.
Disconnect the G1, Cathode, and Filament cable from connector CN108.
3.
Disconnect the Ground connector from connector CN109.
4.
Disconnect the G2 Output connector from connector CN107.
5.
Disconnect the Focus Lead (grey connector, see Figure 4-15).
6.
Disconnect the Anode Lead (large black connector, see Figure 4-15).
7.
Disconnect the Deflection cable that is plugged into the Vertical
Convergence Deflection PCB.
8.
Remove the Deflection cable from all the tie wraps.
9.
Disconnect the ILA
®
Bias connector
10.
Remove the 2 slotted head screws near the rear of the ILA
®
Assembly.
NOTE:
If removing the Green CRT/ILA
®
, remove the Thermistor
attached to the Green ILA
®
.
11.
Loosen the 2 Phillips-head screws holding the clamp on the CRT shield.
12.
Pull the CRT/ILA
®
Assembly out of the projector.
13.
Replace the CRT/ILA
®
Assembly in the reverse order.
Figure 4-15
ILA
®
Assembly top view.
CRT Clamp
Screws
(one screw on
each side)
ILA
®
Mount
Screws
Summary of Contents for 100
Page 12: ...Chapter 1 Introduction 1 4 Model 100 Service Manual ...
Page 63: ...Chapter 2 System Description Model 100 Service Manual 2 51 ...
Page 67: ......
Page 115: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 11 Various Problems ...
Page 117: ...Chapter 5 Troubleshooting Model 100 Service Manual 5 13 ...